NetBackup status code: 1515

NetBackup status code : 1515
HOWTO91323 | 2013-10-02
How To | CMS-XML

NetBackup status code: 1515

NetBackup status code : 1515
HOWTO51641 | 2012-11-19
How To | CMS-XML

NetBackup status code: 1515

NetBackup status code : 1515
HOWTO35751 | 2010-10-29
How To | CMS-XML

Backups to Media Server fail with Status 806 & Status 811 after upgrading to NBU 7.x

21:08:47.838 [8355] 2 vnet_cached_getaddrinfo_and_update: ../../libvlibs/vnet_addrinfo.c.1514: 0: found in file cache name: 10.x.y.z 21:08:47.838 [8355] 2 vnet_cached_getaddrinfo_and_update: ../../libvlibs/vnet_addrinfo.c. 1515 : 0: found in file cache service: NULL
TECH167641 | 2012-06-25
Technical Solutions | CMS-XML

Status Code Chart

1514 1515 1516
TECH58686 | 2014-02-18
Technical Solutions | CMS-XML

Status code 59 on Exchange 2010 Restores when there is a hardware Network Load Balancer

09:35:45.075 [7792.6732] 2 vnet_cached_getaddrinfo_and_update: ../../libvlibs/vnet_addrinfo.c.1514: 0: found in file cache name: master-server 09:35:45.075 [7792.6732] 2 vnet_cached_getaddrinfo_and_update: ../../libvlibs/vnet_addrinfo.c. 1515 : 0: found in file cache service: NULL
TECH163033 | 2013-12-30
Technical Solutions | CMS-XML

Status 811 failed to communicate with resource requester

15:09:36.801 [4762] 2 vnet_cached_getaddrinfo_and_update: ../../libvlibs/vnet_addrinfo.c.1514: 0: found in file cache name: 172.18.120.189 15:09:36.801 [4762] 2 vnet_cached_getaddrinfo_and_update: ../../libvlibs/vnet_addrinfo.c. 1515 : 0: found in file cache service: NULL
TECH180004 | 2013-03-27
Technical Solutions | CMS-XML

error RMAN | Symantec Connect

17:41:37.643 [19541] <2> ConnectToBPCD: db_getclient(geo-v890_2) failed: 227 17:41:37.643 [19541] <2> vnet_cached_getaddrinfo_and_update: ../../libvlibs/vnet_addrinfo.c.1514: 0: found in file cache name: NULL 17:41:37.644 [19541] <2> vnet_cached_getaddrinfo_and_update: ../../libvlibs/vnet_addrinfo.c. 1515 : 0: found in file cache service: bpcd
Connect Forums | HTML

BUG REPORT: nbdb_move reports Move of database files failed

13:30:12.620 [7914] 2 vnet_cached_getaddrinfo_and_update: ../../libvlibs/vnet_addrinfo.c.1514: 0: found in file cache name: tinbubm2800p 13:30:12.620 [7914] 2 vnet_cached_getaddrinfo_and_update: ../../libvlibs/vnet_addrinfo.c. 1515 : 0: found in file cache service: NULL 13:30:12.628 [7914] 4 nbdb_move: SQLANY = /usr/openv/db
TECH217020 | 2014-05-16
Technical Solutions | CMS-XML

Unable connect to JAVA console because Private Branch Exchange (PBX) port 1556 was changed.

12:38:45.585 [3696] 4 bptm: emmserver_port = 1556 12:38:45.622 [3696] 2 vnet_cached_getaddrinfo_and_update: ../../libvlibs/vnet_addrinfo.c.1514: 0: found in file cache name: NULL 12:38:45.622 [3696] 2 vnet_cached_getaddrinfo_and_update: ../../libvlibs/vnet_addrinfo.c. 1515 : 0: found in file cache service: veritas_pbx
TECH162521 | 2013-10-04
Technical Solutions | CMS-XML

Using bptestnetconn to test connectivity between NetBackup hosts

12/07/2011 07:58:08.027 [Debug] NB 51216 libraries 137 PID:28355 TID:1123518784 File ID:222 [No context] 1 [vnet_cached_getaddrinfo_and_update] ../../libvlibs/vnet_addrinfo.c. 1515 : 1123518784: found in file cache service: NULL
HOWTO61210 | 2013-04-30
How To | CMS-XML

can we run backup command on media server | Symantec Connect

NetBackup status code: 240 05:52:16.265 [5060.2260] <2> vnet_cached_getaddrinfo_and_update: ../../libvlibs/vnet_addrinfo.c. 1515 : 0: found in file cache service: NULL
Connect Forums | HTML

system state backup failure on window 2008 server | Symantec Connect

14:32:46.510 [4488.3472] <2> vnet_cached_getaddrinfo_and_update: ../../libvlibs/vnet_addrinfo.c. 1515 : 0: found in file cache service: NULL
Connect Forums | HTML

NBU 7.1.0.2 - Import Images after cleanup catalog | Symantec Connect

[4945] <2> bpcd valid_server: comparing rozrhbckb01 and rozrhbckp02 15:16:50.361 [4945] <2> vnet_cached_getaddrinfo_and_update: ../../libvlibs/vnet_addrinfo.c.1514: 0: found in file cache name: rozrhbckb01 15:16:50.361 [4945] <2> vnet_cached_getaddrinfo_and_update: ../../libvlibs/vnet_addrinfo.c. 1515 : 0: found in file cache service: NULL 15:16:50.361
Connect Forums | HTML