NetBackup Enterprise Server Search Results


Knowledge Base Search         Search Tips


   

Symantec Suggests

  Next 

NetBackup status code: 270

NetBackup status code : 270
HOWTO90679 | 2013-10-02
How To | CMS-XML

NetBackup status code: 270

NetBackup status code : 270
HOWTO51027 | 2012-11-19
How To | CMS-XML

NetBackup status code: 270

NetBackup status code : 270
HOWTO35138 | 2010-10-29
How To | CMS-XML

Active Directory GRT restore failing with status code 2808 and 5

10/8/2013 19:39:58.920 [[fsys\adgran] ] FROM BEDS ADGran : Restoring object of size 0x16 in adgran_writeobj: 270 (../BEDSContext.cpp:124)
TECH211394 | 2013-10-14
Technical Solutions | CMS-XML

CORBA connection failures and status 25 after upgrading media server to 7.5.0.6 or 2.5.3

...snip... 17:19:33. 270 [1711] 16 setup_twin_parameters: INF - cannot connect on socket (25) , cannot continue with copy 1
TECH208869 | 2013-09-24
Technical Solutions | CMS-XML

After upgrading NetBackup, NDMP backups start to fail reporting status code 84 and bptm reports "too many data blocks written" errors in its log.

22:16:20.200 [3277] 2 io_terminate_tape: absolute block position prior to writing empty header is 16943749, copy 1 22:16:20. 270 [3277] 2 io_terminate_tape: block position check: actual 16943749, expected 166533 16 io_terminate_tape: FREEZING media id ABC123, too many data blocks written, check tape/driver block size configuration
TECH165850 | 2011-12-19
Technical Solutions | CMS-XML

GENERAL ERROR: Windows 2003 Event Logs are selected for restore to an alternate location. The restore completes, but the files are not restored.

09/08/2007 03:49 PM DIR .. 09/08/2007 03:46 PM 270 ,136 AppEvent.Evt 09/08/2007 03:46 PM 16,776,756 SecEvent.Evt
TECH52749 | 2011-11-24
Technical Solutions | CMS-XML

"error connecting to oprd network protocol error" when configuring devices on a new media server

10:11:40. 270 [4854] 2 vnet_async_connect: vnet_vnetd.c.4228: connect: async CONNECT FROM 172.30.210.199.58795 TO 10.19.96.11.13724 fd = 5 10:11:40.270 [4854] 2 logconnections: BPDBM CONNECT FROM 172.30.210.199.58795
TECH163933 | 2011-08-15
Technical Solutions | CMS-XML

Many small jobs in a large MPX group may result in slow performance and status 13 or status 6

12:28:09.523 [22497] 4 write_backup: successfully wrote backup id myclient_1249906289, copy 1, 1058 Kbytes 12:28:34. 270 [22497] 2 read_brm_msg: START BACKUP ... 12:29:03.295 [22497] 2 read_brm_msg: START BACKUP ...
TECH135606 | 2011-04-26
Technical Solutions | CMS-XML

BUG REPORT: After installation of an engineering binary for nbpem (v5), policies which have schedules with 52 week retention and multistreaming enabled fail with status code 196 reported.

25/09/08 10:45:53. 270 [Debug] NB 51216 nbpem 116 PID:16806 TID:57383840 File ID:116 [No context] 5 [] (ID:0x95e3d80) Queue Task Handler (MT) call run on task ID:0x95d6eb8, parameter 0x1a, event ID:0(PemHandlerEntry.cpp:50)
TECH65544 | 2009-01-26
Technical Solutions | CMS-XML

Windows Java GUI hangs or receives error code status 195, when trying to display details under " Media and Device Management "

05/21/2009 21:03:35.893 [Debug] NB 51216 137 PID:10380 TID:1 File ID:132 [No context] 6 [EndpointSelector::select_endpoint] --- EXITING --- : obj = 1441530 (endpoint_selector.cpp: 270 )
TECH71174 | 2009-01-20
Technical Solutions | CMS-XML

GENERAL ERROR: Attempting to install 6.0 MP4 maintenance packs without executing preinstall and postinstall scripts can lead to unexpected results.

EMM interface initialization failed, status = 77 /path/to/install/vrtsnb_60_4_m.postinstall: line 270 : 11034 Aborted ${vm_bin}/tpext ERROR: tpext command failed.
TECH51964 | 2007-01-14
Technical Solutions | CMS-XML

RESTORE failing with error 12 | Symantec Connect

RESTORE failing with error 12 13:17:14.269 [23443] <2> hosts_equal: hostbuf=a11 hostentry->h_name=asm03 13:17:14. 270 [23443] <2> hosts_equal: compare a11 with alias asm03 13:17:14.270 [23443] <2> hosts_equal: there were NO aliases for a11
Connect Forums | HTML

NDMP bakup failing with status 99 | Symantec Connect

14:20:24. 270 [4665] <2> db_end: Need to collect reply 14:20:33.052 [4665] <2> ConnectionCache::connectAndCache: Acquiring new connection for host ampsnbma, query type 78 14:20:33.078 [4665] <2> vnet_pbxconnect: pbxConnectEx Succeeded
Connect Forums | HTML

Netbackup Error | Symantec Connect

I created a log folder (/usr/openv/netbackup/logs/admin) the following log was generated 15:24:12.269 [26410] <2> file_to_addrinfo: ../../libvlibs/vnet_addrinfo.c.5662: 0: fopen() failed: /usr/openv/var/host_cache/06b/c413626b+veritas_pbx,1,20,2,1,0+localhost.txt 15:24:12. 270 [26410] <2> file_to_addrinfo: ../../libvlibs/vnet_addrinfo.c.5661: 0: fopen() failed: 2 0x00000002
Connect Forums | HTML
  Next 