- Change Language
bv-Control for Windows
Technical Solution
-
Connection to the Bindview Query Engine (QE) on "HOSTNAME" failed. Verify the service is running the proper version and that the credentials if needed have been entered. The interface is unknown!
Doc. ID: TECH115523 | 2012-01-25 -
What file(s) do I need to edit to change the questionnaire website link for RAM?
Doc. ID: TECH155640 | 2012-02-27 -
Error when applying the 2010-4 MQE update; Starting Service (bvntqe) on computer (hostname) failed...The service did not start due to a logon failure.
Doc. ID: TECH145905 | 2011-07-01 -
What log files to collect and send TSE for troubleshooting a Control Compliance Suite ( CCS ) Data Collection Cumulative Hotfix. ( CHF ) failure.
Doc. ID: TECH115186 | 2012-02-23 -
No More endpoints available from the endpoint mapper.
Doc. ID: TECH113064 | 2008-01-30 -
Registry checks fail with error: HRESULT E_FAIL Has Been Returned from a call to a COM component
Doc. ID: TECH180165 | 2012-03-15 -
Upgrade through “Automatic Updates Installation Job” fails
Doc. ID: TECH188669 | 2012-05-14 -
How to reset the Bindview Service Account password - Data Collection
Doc. ID: TECH113908 | 2009-01-25 -
How To Obtain the Latest Version of Symantec Control Compliance suite and Cumulative Hotfix
Doc. ID: TECH113916 | 2010-10-18 -
An error appears when running bv-Control for Windows Query "Agent Timed out. Unable to execute atomic job... agent hung. Error code 1235".
Doc. ID: TECH113976 | 2011-09-29 -
Event IDs 11092 and 14012 in application event logs on computers hosting Query Engines (QEs)
Doc. ID: TECH113926 | 2008-01-07 -
"Remote script failure detected. Error code 2. Setup will abort Remote Script in xxx seconds." while trying to install Query Engine (QE) or ECS onto a 64-bit machine.
Doc. ID: TECH115735 | 2011-02-03 -
List of ports used by Query Engine.
Doc. ID: TECH113583 | 2011-09-28 -
SetSpn -L your_appserver_service_account_name fails : 'SetSnp' is not a recognized as an internal or external command
Doc. ID: TECH134289 | 2012-01-25 -
How to manually update Patch Assessment files in bv-Control for Windows v.8.50 and above.
Doc. ID: TECH113776 | 2010-09-15 -
How does the WSUS Patch Assessment query work in bv-control for Windows
Doc. ID: TECH142244 | 2012-08-18 -
Event ID 537 with status code 0xC000005E appears in the Security log
Doc. ID: TECH114364 | 2008-01-21 -
Error: "Unable to execute atomic job
on SQE(SQE_Name) because of an error. Error Message: (AtomicJobBase::Execute(): A required privilege is not held by the client." while running queries using bv-Control for Windows
Doc. ID: TECH200054 | 2013-02-10 -
What update file is used to upgrading CCS 9.0 to CCS 9.0.1 SP1 is not listed?
Doc. ID: TECH131367 | 2012-01-25 -
Scheduled queries do not show up in task status when they run.
Doc. ID: TECH148108 | 2011-09-25