Symantec Software Virtualization Solution™ 2.1 SP2

Build number 2.1.3062

Release Notes

Introduction

Installation and Upgrade

What's New in this Release

Fixes in this Release

Known Issues in this Release

Additional Documentation

Document History

Introduction

Symantec Software Virtualization Solution is a revolutionary approach to software management. It lets you put applications and data into managed units called Virtual Software Packages (VSPs). When you put an application into a VSP, you completely avoid conflicts between the application and other applications installed on a computer. You can also instantly activate, deactivate, or reset the application. If an application is broken, you can reset it to return it to its original state.

Software Virtualization Solution is available in two versions:

  • The commercial version lets you create and distribute Virtual Software Packages.
  • The free version for personal use lets you create and use your own virtual layers on your home or personal computer. For more information, see
    http://juice.altiris.com/svs.

This document provides information about installation, upgrade, new features, fixes, known issues, and documentation for Software Virtualization Solution.

Installation and Upgrade

Prerequisites

Prerequisites for Software Virtualization Solution Agent:

  • Access to the application setup files that you intend to virtualize.
  • One of the following client operating systems:

    Microsoft Windows Vista SP1 32-bit
    Microsoft Windows 2000 Professional SP4 or later
    Microsoft Windows 2000 Advanced Server SP4 or later when used as a client
    Microsoft Windows XP Professional SP2 or Home Edition SP2 or later
    Microsoft Windows Server 2003 or later when used as a client
    Microsoft Windows Server 2008 when used as a client

Prerequisites for Software Virtualization Solution with the Notification Server Platform:

  • Altiris Notification Server 6.0 SP3 R4 or later with the Altiris Agent 6.0 or later installed on client computers.

Prerequisites for Software Virtualization Solution with the Deployment Server Platform:

  • Altiris Deployment Solution 6.8 or later with the Deployment Agent installed on client computers.

Where to Download

You can download released versions of Altiris products from http://www.altiris.com/Download.aspx.
You can also download released versions of Software Virtualization Solution from http://www.getsvs.com.

New Installation

For new installation information, please see the installation topics in the Symantec Software Virtualization Solution User's Guide.

Upgrade Issues

Issue Article ID
Recommendation: Backup pre-existing layers before upgrading

You can install Software Virtualization Solution 2.1 SP2 over an existing Software Virtualization Solution 2.0 installation. Before you do this, create a backup of pre-existing layers by exporting them. Software Virtualization Solution 2.1 uses a new layer format. When you upgrade from 2.0 to 2.1, existing layers are automatically converted to this new format. However, if you need to roll back to 2.0, you cannot revert layers back to the 2.0 format . Therefore, we recommend that you back up layers before you upgrade.

 
Issue: Upgrading the Symantec SVS applet

Following an upgrade, the Symantec SVS applet is not available.

35363

Upgrade Steps

Upgrading Software Virtualization Solution

You can upgrade the solution over an existing 2.0 installation.

If you uninstall Software Virtualization Solution 2.0 or earlier, existing Virtual Software Packages (layers) on that computer are deleted. To preserve the existing layers, you should use one of the following methods to upgrade the solution.

In a Notification Server 7.0 environment

  • In the Software Catalog, for the Software Virtualization Agent, create and use the following command
    msiexec.exe /qb /i Software_Virtualization_Agent.msi REINSTALL=ALL REINSTALLMODE=vomus PRODUCT_KEY='PRODUCTKEY'
    This requires a client computer restart.

In a Notification Server 6.x environment

  • Use the Software Virtualization Agent Upgrade policy. This requires a client computer restart.

In a network environment not using Notification Server

  • Run Software_Virtualization_Agent.exe. This requires a computer restart.
  • You can also use the following command line:
    msiexec.exe /qb /i Software_Virtualization_Agent.msi REINSTALL=ALL REINSTALLMODE=vomus PRODUCT_KEY='PRODUCTKEY'
    This requires a client computer restart.

For Software Virtualization Solution for Personal Use

  • Run Software_Virtualization_Agent.exe.
    This requires a computer restart.

What's New in this Release

Improvements for this release include the following new features:

Integration with Notification Server 7.0 

With Notification Server 7.0, Software Virtualization Solution is no longer a solution that plugs into the Notification Server platform. The ability to deliver and manage Virtual Software Packages is now part of the Software Management Solution. Software Virtualization Solution is now a stand-alone product that lets you create Virtual Software Packages that you can deliver and manage with Software Management Solution.

Support for Microsoft Windows Vista SP1

You can run this version of the Software Virtualization Solution Agent on computers using Microsoft Windows Vista SP1 32 bit.

Note: 64-bit operating systems are not supported at this time.

Support for Microsoft Windows Server 2008

You can run this version of the Software Virtualization Solution Agent on computers using Microsoft Windows Server 2008.

Multiple file import in Symantec Software Virtualization Solution Admin (SVS Admin)

You can now import multiple .vsa files at the same time into the SVS Admin.

Fixes in this Release

The following issues were resolved in this release. For additional information regarding a fixed issue click the Article ID link.

Fix Article ID
On a Windows Vista operating system, if one user logged off and another user logged, the SVS user variables were not loaded and specific sub-folders were not created for the second user. This has been fixed. 39225
The SVSCMD executable can now reference a GUID when exporting a layer.
 The Symantec SVS applet now supports the SVS runtime mode.  37870
Multiple internationalization problems were fixed.
Multiple issues that caused blue screens were fixed.

Issues causing user variables to resolve incorrectly the first time a user logs on to a Windows Vista computer were fixed.

 
An issue causing Microsoft's User Profile Hive Cleanup service (UPHClean) to freeze at "Saving your settings ..." was fixed.  
Blue screen issues on computers running McAfee Antivirus were fixed.  

Known Issues and Things to Know

The following are unresolved issues in this release. For additional information regarding a known issue, click the Article ID link.

Known issues specific to Software Virtualization Solution and Microsoft Vista Compatibility Article ID
Transactions

Software Virtualization Solution 2.1 SP2 does not support applications using transactions during the installation on Vista. Office 2007 and Adobe 8 both run transactions during capture. The current work-around is to create the Virtual Software Package on a different operating system.

33508
Creating a string value in a registry during capture

If you create a registry string value when you capture a layer, two values are created and the string data is put in the second registry value. The current work-around is to create the Virtual Software Package on a different operating system.

34123
Elevation issue with dragging and dropping files into the Edit Layer dialog box

When logged onto a Windows Vista computer, as a limited user or a regular admin, dragging and dropping files in the Edit Layer dialog box fails.

This issue occurs only on Windows Vista computers when elevated rights are required. This problem does not occur when you run Symantec Software Virtualization Solution Admin on a Windows Vista computer as an elevated administrator.

34118
SVSCMD requires the administrator token

You must run SVSCMD in a process that uses the Administrator token.

34119
Office launches repair

When you launch Microsoft Office 2003 or 2007 for the first time as a limited user, Microsoft Word performs a repair. This repair does not effect operation.

33510
User Account Control warning with Software Virtualization Solution installation

When you install Software Virtualization Solution on a Windows Vista computer, a User Account Control dialog box informs you that "An unidentified program wants access to your computer." To install Software Virtualization Solution, select Allow. I trust this program. I know where it's from or I've used it before.

 
Variables not valid on Windows Vista computers

The Variables COMMONFAVORITES and LOCALSETTINGS do not resolve on a Windows Vista computer.

35349
 Fatal error occurs when you attempt to perform a repair of the Software Virtualization Agent installation

If you install the Software Virtualization Agent on a Windows Vista computer and then try to repair the installation under User Account Control, you encounter a fatal error. The workaround is to perform the repair as a domain administrator, the computer administrator, or from a command line as an elevated user. 

 

Additional Known Issues Article ID
Layers Created with 2.1 SP2 are not backward compatible with 2.0

Layers created in Software Virtualization Solution 2.1 SP2 do not work with Software Virtualization Solution 2.0 because of a change of format.

34120
Short file names do not resolve properly

Programs that store path information in the registry that use short file names (for example, C:\progr~1 instead of C:\Program Files) might not function correctly when virtualized. This is an issue only if the base or a program in another layer uses the same short name abbreviation for a similar but different path. To resolve this issue, install the program to a directory where the first six characters of the folder name are unique.

30877
Files saved to a non-system drive may not be visible when a layer is exported

If a file is saved into a layer on a drive other than the system drive (the C drive on most computers), the file may not appear when the layer is exported and imported onto another computer.

33511
Fonts in a layer are not available to the application

When using an application that is in a layer, some of the application's fonts may not display correctly. The work-around is to move the fonts to the base. A utility has been developed to move a layer's fonts to the base. See http://juice.altiris.com/tech-tip/270/problems-with-svs-and-fonts-try-this.

20884
Altiris Recovery Solution cannot complete a full snapshot

Altiris Recovery Solution cannot complete a full snapshot on computers running Software Virtualization Solution.  To resolve this issue, add an exclusion to the ProgramIgnoreList value in the registry for the Recovery Solution agent.

20863
Registry permissions not checked in priority order

When Software Virtualization Solution checks registry permissions, it does not do it in priority order. It checks the base first.

Intermittent crashes in wininet.dll

In some instances, a virtualized application has caused wininet.dll to crash.

21394
Acrobat Reader 7.x update may not install correctly

Acrobat Reader 8 does not have this problem.

21361
Shortcuts not saved in layers

If you create a shortcut that references an application in a layer after the creation of the layer, the shortcut is not saved in the layer. The shortcut still appears when the layer is deactivated.

32716
A blue screen sometimes appears when a computer is restarted after the installation of the Software Virtualization Agent

On computers that use a non-English Windows operating system and that have Symantec AntiVirus for Windows installed, a blue screen may appear after the Software Virtualization Agent is installed and the computer is restarted. To resolve this problem, install the SAVCE9_KStackMinFree.reg file. This reg file creates a KStackMinFree registry value of 2200 that resolves the problem. You can download this registry file at http://service1.symantec.com/SUPPORT/ent-security.nsf/docid/2002071208532048

 
Delete Layer from Software Virtualization Solution does not report the event to Notification Server

When a layer is deleted on a client computer, the event is not reported to Notification Server. This issue causes the Notification Server database to be out of sync with what is actually on the client computer and causes errors when trying to perform other actions on the layer. 

34125
SVScontrol.cpl does not work on a Windows 2000 computer

On a Windows 2000 computer, you cannot start the Symantec SVS applet with the svscontrol.cpl command line. You can start the Symantec SVS applet from the Control Panel.

 
Symantec SVS applet does not work on a Windows 2008 computer

On a Windows 2008 computer, you cannot start the Symantec SVS applet.

 
Broken links to SVS task icons

If you upgrade or repair Task Server on a Notification Server 6.x, any links to the icons of existing SVS Tasks are broken. The tasks are still functional but the icons do not appear. To repair the links to the icons, run a repair of Altiris SVS Task in Add Remove Programs.

 
SVS archives located on a drive other than the system drive fail to import in the Altiris Console

When adding a new SVS archive for distribution in the Altiris Console, the operation fails if the archive is located on a drive other than the system drive. As a workaround, copy the SVS archive to the system drive before adding in the Altiris Console.

 

Things To Know
Fortress filter driver and running Windows in Safe Mode

The SVS Fortress filter driver is not loaded when a computer is started in Windows Safe Mode. Therefore, any diagnostic or recovery utilities that run in safe mode should not be installed in a layer.

Restart required after the installation of the Software Virtualization Agent

After the Software Virtualization Agent is deployed and installed, the client computer must be restarted for the agent to become active.

Clean machine captures

We recommend that you build your virtual software archive files on a clean machine. This ensures that all required files and registry settings are captured in the package.

How Altiris Recovery Solution backs up Virtual Software Packages

Because Software Virtualization Solution redirects files in Virtual Software Packages, program and data files that are in layers are not backed up in the regular file system. Consequently, you cannot view them in the Recovery utilities. However, the redirect files in the C:\fslrdr directory are backed up.

For example, if you have Microsoft Office in an active layer, the C:\Program Files\Microsoft Office directory appears. These files are actually redirected to C:\fslrdr. When you do a snapshot or recovery, the C:\Program Files\Microsoft Office folder is not recognized.

Additional Documentation

Product documentation is posted on the Beta portal as a PDF document. The name of the file is softwarevirtualization_2.1_sp2_user_guide.pdf.

The following United States Patents have been issued for Software Virtualization Solution technology. Additional patents pending. Patent documentation may be found at http://www.USPTO.gov.

  • 7162724
  • 7165260
  • 7117495
Altiris Information Resources

Source What Information it Includes Location
Altiris Documentation Information about new features, update instructions, and known issues for each release. Includes Altiris formal documentation such as release notes, help, reference guides, best practice articles, and technical reference articles. http://www.altiris.com/support/documentation
Altiris Knowledgebase Comprehensive collection of articles, incidents, and issues for Altiris solutions. http://kb.altiris.com/
Altiris Juice:
an online magazine for Altiris users
Best practices, tips and tricks, and articles for users of Altiris solutions. http://juice.altiris.com
Online Forums Forums for Altiris solutions and suites. http://forums.altiris.com/

Document History

Date Changes
2008/08/13 Initial release.



Legacy ID



40553


Article URL http://www.symantec.com/docs/DOC1560


Terms of use for this information are found in Legal Notices