BulkUploadThreads

Article:HOWTO57461  |  Created: 2011-08-01  |  Updated: 2013-07-12  |  Article URL http://www.symantec.com/docs/HOWTO57461
Article Type
How To


Subject


BulkUploadThreads

Location

On a 32-bit installation of Windows:

HKEY_LOCAL_MACHINE
 \SOFTWARE
  \KVS
   \Enterprise Vault
    \FSA
      \Reporting

On a 64-bit installation of Windows:

HKEY_LOCAL_MACHINE
 \SOFTWARE
  \Wow6432Node
   \KVS
    \Enterprise Vault
     \FSA
      \Reporting

Content

DWORD.

An integer in the range 1 to 10.

Description

BulkUploadThreads specifies the maximum number of FSAReporting data upload threads per file server. The data upload threads collect data from the scan threads, and then upload the data to the FSA Reporting database.

The BulkUploadThreads registry value does not exist by default. If BulkUploadThreads is not specified, FSAReporting uses up to three data upload threads per file server.

If the scan threads queue large amounts of data for upload simultaneously, you can use BulkUploadThreads to increase the number of available data upload threads.

For Windows file servers, set this registry value on the file server. For NetApp and EMC Celerra/VNX file servers, set this registry value on the FSA Reporting proxy server.

See also

See ScanThreads.

See List of File System Archiving registry values


Legacy ID



v32580180_v41328148


Article URL http://www.symantec.com/docs/HOWTO57461


Terms of use for this information are found in Legal Notices