How to enable trace logging for Out of Band Management OOBM Solution

Article:HOWTO7211  |  Created: 2007-04-19  |  Updated: 2007-06-22  |  Article URL http://www.symantec.com/docs/HOWTO7211
Article Type
How To



Question
How do I enable trace-level logging for Out of Band Management Solution?

Answer

  1. Go to Start > Run, type Regedit, and click OK.
  2. Browse to HKEY_LOCAL_MACHINE > SOFTWARE > Altiris > eXpress > Notification Server > ProductInstallation > {09954bad-a09c-43ce-b8ad-407b6b93c936}.
  3. Create a DWORD value named TraceLevel.
  4. Set the value at 255 Decimal, FF hex.
  5. Download dbgview.exe (DebugView from Sysinternals/Microsoft) from www.sysinternals.com (you'll be redirected to Microsoft), click into the Miscellaneous section, and download Debugview.
  6. Execute dbgview.exe.
  7. Now walk through the function you wish to capture trace level logging on.
  8. The debug windows should fill up with entries.
  9. Use the Save command when trace logging in complete.

Legacy ID



34418


Article URL http://www.symantec.com/docs/HOWTO7211


Terms of use for this information are found in Legal Notices