Configure Device panel options for enclosure selection

Article:HOWTO78743  |  Created: 2012-08-24  |  Updated: 2012-08-24  |  Article URL http://www.symantec.com/docs/HOWTO78743
Article Type
How To

Product(s)

Subject


Configure Device panel options for enclosure selection

This topic applies to Veritas Operations Manager Storage Insight Add-on for Deep Array Discovery and Mapping 5.0.

Use this wizard panel to specify the details of the devices, and the server information for configuring deep discovery for the following enclosures:

Table: Configure Device panel options for HITACHI enclosure lists the options for HITACHI enclosures.

Table: Configure Device panel options for EMC Symmetrix enclosure lists the options for EMC Symmetrix enclosures.

Table: Configure Device panel options for IBM XIV enclosures lists the options for IBM XIV enclosures.

Table: Configure Device panel options for NetApp enclosures lists the options for NetApp enclosures.

Table: Configure Device panel options for EMC CLARiiON enclosures lists the options for EMC CLARiiON enclosures.

Table: Configure Device panel options for HP EVA enclosure lists the options for HP Enterprise Virtual Array (EVA) enclosures.

Table: Configure Device panel options for IBM System Storage DS enclosure lists the options for IBM System Storage DS enclosures.

Table: Configure Device panel options for EMC Celerra enclosure lists the options for EMC Celerra enclosures.

Table: Configure Device panel options for EMC VNX enclosure lists the options for EMC VNX enclosures.

Table: Configure Device panel options for EMC VPLEX enclosure lists the options for EMC VPLEX enclosures.

Table: Configure Device panel options for 3PAR enclosure lists the options for 3PAR enclosures.

Table: Configure Device panel options for HITACHI enclosure

Field

Description

Primary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain.

Secondary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain. This host acts as a backup if the primary discovery host fails.

HiCommand Server

Enter the name of the HiCommand server.

Port

The port number of the HiCommand server. By default, the port number is 2001.

Username

Enter the user name for the HiCommand server.

Password

Enter the password for the HiCommand server.

See Configuring deep discovery for HITACHI storage enclosures using Veritas Operations Manager Storage Insight Add-on for Deep Array Discovery and Mapping 5.0.

Table: Configure Device panel options for EMC Symmetrix enclosure

Field

Description

Primary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain.

Secondary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain. This host acts as a backup if the primary discovery host fails.

SymCLI Location

Use Default

Choose this option if you have stored the SymCLI binaries on the default location.

You must ensure that the SymCLI binaries are available on the primary and the secondary discovery hosts.

Custom

Choose this option if you have stored the SymCLI binaries on any other location. Enter the path to the location in the field.

You must ensure that the SymCLI binaries are available on the primary and the secondary discovery hosts.

Enable performance metering

Enables the performance metering for the enclosure.

Clear the check box to disable performance metering.

See Configuring deep discovery for EMC Symmetrix storage enclosures using Veritas Operations Manager Storage Insight Add-on for Deep Array Discovery and Mapping 5.0.

Table: Configure Device panel options for IBM XIV enclosures

Field

Description

Primary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain.

Secondary Discovery Host

Enter the name of the host.

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain. This host acts as a backup if the primary discovery host fails.

IBM XIV Server Name/IP 1

The IP address for the XIV system. The Storage Insight Add-on uses this IP address to connect to the XIV system using the XCLI utility.

IBM XIV Server Name/IP 2

The IP address for the XIV system. The Storage Insight Add-on uses this IP address to connect to the XIV system using the XCLI utility, if the IP address that you have specified in the previous field is not accessible.

IBM XIV Server Name/IP 3

The IP address for the XIV system. The Storage Insight Add-on uses this IP address to connect to the XIV system using the XCLI utility, if the IP addresses that you have specified in the previous two fields are not accessible.

Username

Enter the user name for the XIV system.

Password

Enter the password for the XIV system.

XCLI Location

The location of the XCLI utility on the primary and the secondary discovery hosts.

You must ensure that the XCLI utility is available on the primary and the secondary discovery hosts.

Enable performance metering

Enables the performance metering for the enclosure.

Clear the check box to disable performance metering.

See Configuring deep discovery for IBM XIV storage enclosures using Veritas Operations Manager Storage Insight Add-on for Deep Array Discovery and Mapping 5.0.

Table: Configure Device panel options for NetApp enclosures

  

Primary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain.

A host that runs on Solaris, Linux, or Windows can be designated as a primary discovery host.

Secondary Discovery Host

Enter the name of the host.

This host must be a part of theVeritas Operations Manager Management Server domain. This host acts as a backup if the primary discovery host fails.

A host that runs on Solaris, Linux, or Windows can be designated as a secondary discovery host.

NetApp Server

Enter the name or the IP address for the NetApp server.

Port

The port for the NetApp server.

Enter 80 for communicating to the NetApp server over HTTP. For communicating to the NetApp server over HTTPS, enter 443.

You must ensure that the port that you specify here must be enabled on the enclosure.

Username

Enter the user name for the enclosure.

Password

Enter the password for the enclosure.

Enable NAS discovery

Select the checkbox to enable the NAS discovery for the NetApp enclosure.

NAS discovery is a Veritas Operations Manager Advanced feature. You can temporarily use the feature under a demo license of Veritas Operations Manager Advanced. To obtain a permanent license, you need to accept the End User's License Agreement (EULA) for Veritas Operations Manager Advanced.

See About enabling Veritas Operations Manager Advanced features on Management Server in Veritas Operations Manager 5.0.

Enable performance metering

Enables the performance metering for the enclosure.

Clear the check box to disable performance metering.

See Configuring deep discovery for NetApp storage enclosures using Veritas Operations Manager Storage Insight Add-on for Deep Array Discovery and Mapping 5.0.

Table: Configure Device panel options for EMC CLARiiON enclosures

  

Primary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain.

A host that runs on Solaris, Linux, Windows, AIX, or HP-UX can be designated as a primary discovery host.

Secondary Discovery Host

Enter the name of the host.

This host must be a part of the Veritas Operations Manager Management Server domain. This host acts as a backup if the primary discovery host fails.

A host that runs on Solaris, Linux, Windows, AIX, or HP-UX can be designated as a secondary discovery host.

Hosts that run on the same operating system must be designated as the primary and the secondary discovery hosts. However, you can choose a host that runs on Solaris and a host that runs on Linux as a primary and the secondary discovery host pair if the location of the NaviSecCLI is the same for these two types of hosts.

Storage Array Name/IP

Name or the IP address of the storage enclosure.

Port

The port for communicating to the EMC CLARiiON enclosure for getting the information.

The default port number is 443.

Username

Enter the user name for the EMC CLARiiON enclosure.

Password

Enter the password for the EMC CLARiiON enclosure.

Scope

Specifies the type of the user account on the storage system that you want to log on. The available options are:

  • Global: Choose this option if your account is effective throughout the domain. When the administrator creates a global account, the software copies the definition of this account to the domain directory, which makes it accessible on all storage systems in the domain.

  • Local: Choose this option if your account is effective only on the storage systems for which the administrator creates the account. Using the local account, you can log on to only those storage systems on which you have a local account.

  • LDAP: LDAP maps the user name and the password entries to an external LDAP or Active Directory server for authentication. The user name and the password pairs whose roles are not mapped to the external directory are denied access.

    For authentication within the local security directory, specify global or local scope.

NaviSecCLI Location

The location of the NaviSecCLI binary in the discovery host.

Use Default

Choose this option if you have stored the NaviSecCLI binaries on the default location.

You must ensure that the NaviSecCLI binaries are available on the primary and the secondary discovery hosts.

Custom

Choose this option if you have stored the NaviSecCLI binaries on any other location. Enter the path to the location in the field.

You must ensure that the NaviSecCLI binaries are available on the primary and the secondary discovery hosts.

Use Secure Socket Layer

Select this check box to use the secure socket layer for communicating to the enclosure.

If you select this check box, you do not have to enter the credentials again when you perform deep discovery for the EMC CLARiiON enclosures.

Enable performance metering

Enables the performance metering for the enclosure.

Clear the check box to disable performance metering.

See Configuring deep discovery for EMC CLARiiON storage enclosures using Veritas Operations Manager Storage Insight Add-on for Deep Array Discovery and Mapping 5.0.

Table: Configure Device panel options for HP EVA enclosure

Field

Description

Primary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain.

Secondary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain. This host acts as a backup if the primary discovery fails.

Command View Server/IP

Enter the name, or the IP address of the Command View server.

Username

Enter the user name for the Command View server. Note that along with the root or the admin user, a non-admin user can also perform the discovery.

Password

Enter the password for the Command View server. If you have selected the password file option, you do not need to enter the password.

SSSU CLI Location

Enter the full path for the Storage Scripting System Utility (SSSU) CLI on the primary and secondary discovery hosts.

SSSU Password-File Directory Path

Enter the directory path for the SSSU password file on the primary and the secondary discovery hosts. This file is generated using the SSSU utility. If you have already specified the password in the Password field, this entry is ignored.

See Configuring deep discovery for HP EVA storage enclosures using Veritas Operations Manager Storage Insight Add-on for Deep Array Discovery and Mapping 5.0.

Table: Configure Device panel options for IBM System Storage DS enclosure

Field

Description

Primary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain. This host must have DSCLI utility installed on it. It should also be connected to the enclosure.

Secondary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain. This host acts as a backup if the primary discovery host fails. This host must have DSCLI utility installed at the same location as the primary discovery host. This host should also have network connectivity with the enclosure.

Storage array name/IP

Enter the name, or the IP address for the IBM System Storage DS enclosure.

User Name

Enter the user name for the enclosure.

Password

Enter the password to access the enclosure. Leave this field blank if the discovery is done using the password file.

DSCLI Location

Enter the full directory path of the DSCLI utility on the primary and secondary discovery hosts.

Password File Path

Enter the full path (including the file name) for the password file on the primary and secondary hosts. This field is ignored if the password is provided in the Password field.

See Configuring deep discovery for IBM System Storage DS enclosures using Veritas Operations Manager Storage Insight Add-on for Deep Array Discovery and Mapping 5.0.

Table: Configure Device panel options for EMC Celerra enclosure

Field

Description

Primary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain.

Secondary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain. This host acts as a backup if the primary discovery host fails.

Celerra Control Station

Interface for Celerra communication.

Username

Enter the user name for the enclosure.

Password

Enter the password for the enclosure.

Note:

NAS discovery is a Veritas Operations Manager Advanced feature. You can temporarily use the feature under a demo license of Veritas Operations Manager Advanced. To obtain a permanent license, you need to accept the End User's License Agreement (EULA) for Veritas Operations Manager Advanced.

See Configuring deep discovery for EMC Celerra storage enclosures using Veritas Operations Manager Storage Insight Add-on for Deep Array Discovery and Mapping 5.0.

Table: Configure Device panel options for EMC VNX enclosure

Field

Description

Primary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain.

Secondary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain. This host acts as a backup if the primary discovery host fails.

Control Station IP/Name

Enter the name or the IP address of the VNX File. It is optional for VNX Block only device.

Block IP/Name:Scope

IP address or name and scope for VNX Block. The IP address or name, and the scope must be separated using colon.

It is optional for VNX File only device.

User Name

Enter the user name for the enclosure.

Password

Enter the password for the enclosure.

CLI Location

Enter the Navisphere CLI location.

See Configuring deep discovery for EMC VNX storage enclosures using Veritas Operations Manager Storage Insight Add-on for Deep Array Discovery and Mapping 5.0.

Table: Configure Device panel options for EMC VPLEX enclosure

Field

Description

Primary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain.

Secondary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain. This host acts as a backup if the primary discovery host fails.

VPLEX Array Name/IP

Enter the name, or the IP address of the VPLEX enclosure.

User Name

Enter the user name for the enclosure. To perform the enclosure discovery, you must have administrator privileges.

Password

Enter the password for the enclosure.

Port

Enter the communication port for the VPLEX enclosure. The default communication port is 443.

See Configuring deep discovery for EMC VPLEX storage enclosures using Veritas Operations Manager Storage Insight Add-on for Deep Array Discovery and Mapping 5.0.

Table: Configure Device panel options for 3PAR enclosure

Field

Description

Primary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain.

Secondary Discovery Host

Enter the name of the host. This host must be a part of the Veritas Operations Manager Management Server domain. This host acts as a backup if the primary discovery host fails.

3PAR Enclosure IP/Name

Enter the name or the IP address for the 3PAR enclosure.

User Name

Enter the user name for the enclosure.

Password

Enter the password for the enclosure.

See Configuring deep discovery for 3PAR storage enclosures using Veritas Operations Manager Storage Insight Add-on for Deep Array Discovery and Mapping 5.0.


Legacy ID



v72685305_v71172234