Error "There are no more endpoints available from the endpoint mapper" when running a query in Control Compliance Suite (CCS) Data Collection

Article:TECH114478  |  Created: 2008-01-16  |  Updated: 2008-01-04  |  Article URL http://www.symantec.com/docs/TECH114478
Article Type
Technical Solution


Issue



Error "There are no more endpoints available from the endpoint mapper" when running a query in Control Compliance Suite (CCS) Data Collection


Cause



Connection to the Information Server (IS) fails because of an RPC service error.

Solution



Follow these steps to resolve the issue:
  1. On the IS, Click Start > Run. Type services.msc and press Enter.
  2. Restart the bvProcessManager service.
  3. Restart the RPC Server service.
  4. Run the query again.






Legacy ID



2008051615285853


Article URL http://www.symantec.com/docs/TECH114478


Terms of use for this information are found in Legal Notices