Symantec Enabled Arrays - Array Support Library for HP MSA2000 ( MSA2312fc, MSA2324fc, MSA2012sa, MSA2312sa, MSA2324sa, MSA2312i, MSA2324i, P2000 G3 FC, P2000G3 FC/iSCSI ) Series Arrays in Active/Active-Asymmetric (A/A-A) mode on Veritas Volume Manager (tm) 4.1MP4 and later for Linux
| Article:TECH124417 | | | Created: 2010-01-17 | | | Updated: 2010-01-24 | | | Article URL http://www.symantec.com/docs/TECH124417 |
Problem
Symantec Enabled Arrays - Array Support Library for HP MSA2000 ( MSA2312fc, MSA2324fc, MSA2012sa, MSA2312sa, MSA2324sa, MSA2312i, MSA2324i, P2000 G3 FC, P2000G3 FC/iSCSI ) Series Arrays in Active/Active-Asymmetric (A/A-A) mode on Veritas Volume Manager (tm) 4.1MP4 and later for Linux
Solution
This TechFile
provides information on the Array Support Library (ASL) for HP MSA2000 (
MSA2312fc, MSA2324fc, MSA2012sa, MSA2312sa, MSA2324sa, MSA2312i, MSA2324i, P2000
G3 FC, P2000G3 FC/iSCSI ) Series Arrays in Active/Active- Asymmetric (A/A-A)
mode on Veritas Volume Manager (tm) 4.1MP4 and later for Linux
For general
information about ASLs, see TechNote
http://support.veritas.com/docs/249446
ASL Package
Name: VRTSHP-MSA2000
ASL Package
Description: Array Support Library for HP MSA 2012/2312/2324 series
arrays
ASL Package
Version: 1.0
Supported
versions of Veritas Volume Manager: 4.1MP4 and later
Supported
Arrays: HP MSA Series ( MSA2312fc, MSA2324fc, MSA2012sa, MSA2312sa,
MSA2324sa, MSA2312i, MSA2324i, P2000 G3 FC, P2000G3 FC/iSCSI ) Arrays
Supported
Modes: A/A-A ( Active/Active- Asymmetric )
Installation
Instructions:
1.Before adding
any ASL package, ensure Veritas Volume Manager is installed and
enabled:
#
vxdctl mode
mode:
enabled
2. Create a
directory to download the ASL tar package
#
mkdir /tmp/asl
#
cd /tmp/asl/
3. At the
bottom of this TechFile, click on Download Now to download the package in
/tmp/asl/
4. After
downloading VRTSMSA2000-4.1-1.0_Linux.tar_347423.gz, verify the checksum
of the file
#
cksum VRTSMSA2000-4.1-1.0_Linux.tar_347423.gz
2965789740
22821 VRTSMSA2000-4.1-1.0_Linux.tar_347423.gz
5. Uncompress
the file and extract the packages:
#
gunzip VRTSMSA2000-4.1-1.0_Linux.tar_347423.gz
#
tar -xvf VRTSMSA2000-4.1-1.0_Linux.tar_347423
Note:
Verify that there are four rpm packages as part of the tar ball i.e. one ASL
package per distribution for RHEL4, RHEL5, SUSE9 and SUSE10
Following are
the ASL packages
VRTSMSA2000-4.1-1.0_RHEL4.i686.rpm
VRTSMSA2000-4.1-1.0_RHEL5.i686.rpm
VRTSMSA2000-4.1-1.0_SLES10.i586.rpm
VRTSMSA2000-4.1-1.0_SLES9.i586.rpm
6. Select the
appropriate ASL package depending on the target machine distribution (RHEL or
SLES).
Following are
example installation instructions for SLES9 distribution:
ASL
installation:
#
rpm -ivh VRTSMSA2000-4.1-1.0_SLES9.i586.rpm
7. After the
packages are installed, you must execute the vxdctl
enable command to claim
the disk array
as an array
#
vxdctl enable
Note: In
some cases, it has been reported that the installation of the ASL does not take
effect,
and the
vxdctl enable command does not claim the
enclosure and devices. In such cases,
you can execute
the vxconfigd -k command in addition to
vxdctl enable.
8. After
executing vxdctl enable and
vxconfigd -k, verify the output of
the
vxddladm
listsupport command
# vxddladm listsupport libname=libvxmsa2kfc_sa.so
ATTR_NAME ATTR_VALUE
=========================================
LIBNAME libvxmsa2kfc_sa.so
VID HP
PID MSA2312fc,
MSA2324fc, MSA2012sa
MSA2312sa, MSA2324sa, MSA2312i
MSA2324i, P2000 G3 FC, P2000G3 FC/iSCSI
ARRAY_TYPE
A/A-A
ARRAY_NAME
MSA2312fc, MSA2324fc, MSA2012sa
MSA2312sa, MSA2324sa, MSA2312i
MSA2324i, HP_P2000
9. Verify ASL
library version
#
vxddladm listversion libname=libvxmsa2kfc_sa.so
libvxmsa2kfc_sa.so
has version string: vm-4.1-rev-1. VXVM version: 4.1
ASL Package
Information
#
rpm -qil VRTSMSA2000
Name :
VRTSMSA2000
Relocations
: (not relocatable)
Version
: 4.1
Vendor :
VERITAS Software Corporation Inc.
Release
: 1.0_SLES9
Build
Date : Tue Mar 2 22:30:48 2010
Install
date: Wed Mar 17 02:57:34 2010
Build
Host : vmlx21.veritas.com
Group
: System/Data Storage
Source
RPM : VRTSMSA2000-4.1-1.0_SLES9.src.rpm
Size :
12528
License
: Copyright (c) 1990-2007 VERITAS Software Corporation.
ALL
RIGHTS RESERVED. THIS SOFTWARE IS THE PROPERTY OF AND IS
LICENSED
BY VERITAS SOFTWARE, AND/OR ITS SUPPLIERS.
Signature
: (none)
Packager :
linuxvm-pkgr@veritas.com
URL
: http://www.veritas.com/
Summary
: Array Support Library for HP MSA 2012/2312/2324 series
arrays.
Description
: Array Support Library for HP MSA 2012/2312/2324 series
arrays.
Distribution:
(none)
/etc/vx/aslkey.d
/etc/vx/aslkey.d/libvxmsa2kfc_sa.key
/etc/vx/lib/discovery.d
/etc/vx/lib/discovery.d/libvxmsa2kfc_sa.so
Attachments
|
|
|
Legacy ID
347423
Article URL http://www.symantec.com/docs/TECH124417
Terms of use for this information are found in Legal Notices