KNOWN ISSUE: COM object error on import

Article:TECH12782  |  Created: 2006-03-06  |  Updated: 2007-10-24  |  Article URL http://www.symantec.com/docs/TECH12782
NOTE: If you are experiencing this particular known issue, we recommend that you Subscribe to receive email notification each time this article is updated. Subscribers will be the first to learn about any releases, status changes, workarounds or decisions made.
Article Type
Technical Solution

Issue



NSE from Connector Solution is failing with an error that a COM object has been separated from its underlying RCW and cannot be used.

Environment



Notification Server 6.0.6074
Connector Solution 6.1.1037

Cause



The 5xInterop assembly has become un-registered.

Solution



Open a command prompt and type the following:

CD \Program Files\Altiris\Notification Server\bin
%WINDIR%\Microsoft.NET\Framework\v1.1.4322\RegAsm.exe /codebase Altiris.NS.5xInterop.dll


Supplemental Materials

SourceDEFECT
ValueSYD 22110
DescriptionLogged in sydd2 (Altiris - Sydney) database

Legacy ID



20362