KNOWN ISSUE: COM object error on import
| Article:TECH12782 | | | Created: 2006-03-06 | | | Updated: 2007-10-24 | | | Article URL http://www.symantec.com/docs/TECH12782 |
| NOTE: If you are experiencing this particular known issue, we recommend that you Subscribe to receive email notification each time this article is updated. Subscribers will be the first to learn about any releases, status changes, workarounds or decisions made. |
Problem
NSE from Connector Solution is failing with an error that a COM object has been separated from its underlying RCW and cannot be used.
Environment
Notification Server 6.0.6074
Connector Solution 6.1.1037
Cause
The 5xInterop assembly has become un-registered.
Solution
Open a command prompt and type the following:
CD \Program Files\Altiris\Notification Server\bin
%WINDIR%\Microsoft.NET\Framework\v1.1.4322\RegAsm.exe /codebase Altiris.NS.5xInterop.dll
| Source | DEFECT |
| Value | SYD 22110 |