Restore from tape fails with "0xe00084ca - The data being read from the media is inconsistent"

Article:TECH128063  |  Created: 2010-01-27  |  Updated: 2014-05-26  |  Article URL http://www.symantec.com/docs/TECH128063
Article Type
Technical Solution

Product(s)

Issue



Restore from tape fails with "0xe00084ca - The data being read from the media is inconsistent"


Error



0xe00084ca - The data being read from the media is inconsistent
The following application event occurs :

Event Type: Error
Event Source: Backup Exec
Event Category: Devices
Event ID: 33152
Description:
Adamm Mover Error: Read Failure!
Error = ERROR_CRC
Drive = "HP 1"
{0D8FBEC7-5D0E-4B8F-A77A-63F898CDB510}
Media = "LTO000063"
{C873D6A3-AF09-4995-B94B-F88383C9F922}
Read Mode: SingleBlock(0), ScsiPass(0)
Write Mode: SingleBlock(1), ScsiPass(1)

Running the Tracer.exe utility when attempting the same restore job from the same media reports the following error:

Sense Data
F0 00 03 00 00 00 01 10 00 00 00 00 11 00 00 00
50 84 00 00 P
Filemark False
EOM False
ILI False
Sense key MEDIUM_ERROR
ASC UNRECOVERED_READ_ERROR


Cause



This error will reflect in restore job,when the corrupt tapes or defective tape drives with multiple hard read errors are used during backup.


Solution



1. Check to see if there was any hardware Event IDs with the date matching when the backup was done.

2. Make sure the hardware devices are at the latest firmware and driver level.

3.Check to see is there Multiple "hard" read or write errors indicate a problem with the tape drive ,if so try with different tape drive.

4 If still the same issue run future backups to different tape medium. If the issue persist contact the tape hardware vendor.


Supplemental Materials

SourceError Code
Value0xe00084ca
Description

The data being read from the media is inconsistent.


Legacy ID



348014