VEA GUI failes to login with Error V-39-53247-2 from a client system.

Article:TECH141211  |  Created: 2010-10-04  |  Updated: 2011-02-16  |  Article URL http://www.symantec.com/docs/TECH141211
Article Type
Technical Solution


Environment

Issue



After installing the latest 5.1 AIX VEA gui as per article TECH125166 - HOWTO install Veritas Enterprise Administrator (VEA) GUI for product version 5.1

Starting vea from a client and typing username and password  the connection fails.


Error



Error V-39-53247-2

Error while connecting to 123.4.5.0

Could not connect to server Capabilities mismatch


Environment



AIX 5.3


Cause



Due to some AIX OS JVM libraries that enforce a strict security mechanisms


Solution



Apply AIX hotfix

Please contact Symantec Support for the latest hotfix download. 


Supplemental Materials

SourceETrack
Value2052202
Description

Could not connect to server. Capabilities mismatch, while login through java gui in AIX




Article URL http://www.symantec.com/docs/TECH141211


Terms of use for this information are found in Legal Notices