Disabling multiple paths may casuse a missing disk with Microsoft Clustering.

Article:TECH142812  |  Created: 2010-10-27  |  Updated: 2012-01-19  |  Article URL http://www.symantec.com/docs/TECH142812
Article Type
Technical Solution


Environment

Subject

Issue



On a Storage Fondation 5.1 Service Pack 1 (SP1) for Windows or on a Dynamic Multi-Pathing 5.1 for Windows, Disabling some, but not all, of the paths of a multi-path disk may cause disk loss. This issue has been seen only for HP MSA P2000 array and with Microsoft Clustering.


Solution



To workaround this issue and have the disk reappear, perform either:

1. Rescan in the VEA console by right clicking on Storage agent and selecting rescan.

2. At the command line, run "vxassist rescan" to have the disks reappear.


Supplemental Materials

SourceETrack
Value2107465 : SFW5.1SP1: [HP MSAP2000]Disable three paths make disk missing.


Article URL http://www.symantec.com/docs/TECH142812