Software Virtualization Solution Hotfix 24102 Download

Article:TECH14412  |  Created: 2006-12-04  |  Updated: 2006-12-04  |  Article URL http://www.symantec.com/docs/TECH14412
NOTE: If you are experiencing this particular known issue, we recommend that you Subscribe to receive email notification each time this article is updated. Subscribers will be the first to learn about any releases, status changes, workarounds or decisions made.
Article Type
Technical Solution


Issue



If you are experiencing any of the below problems, upgrade to SVS 2.0 Hotfix 24102:

Article Title  Description  Article ID
User variables do not work when logging off one user and logging on another The user hive fails to unload during logoff so user variables do not set correctly for next user who logs on.  23621
When SVS is installed, users cannot access printer's registry key When SVS layers are set to Activate on Start, the following key cannot be opened: HKEY_LOCAL_MACHINE\SYSTEM\ CurrentControlSet\Control\Print\Printers.  22367
 Error using iprint when SVS layers are activated  When layers are set to autoactivate, Iiprint printers are unavailable  21227
Second Login on a system with SVS Installed is extremely long. After installing SVS, it takes an extremely long amount of time to log onto the system the second time.  22774
SVS causes a blue screen during install. During the install of SVS, a blue screen can sometimes occur.  23835
German string in Layer Editor of SVS is incorrect. A string in the Layer Editor UI was incorrectly translated in the German Language.  24528
Lack of a particular registry value causes most system variables to not be resolved. Some systems do not have a \REGISTRY\MACHINE\ SOFTWARE\Microsoft\Windows\CurrentVersion\Explorer\Shell Folders\ Common Administrative Tools entry which causes FSLX to not load most system variables.  25046


Environment



This upgrade is SVS 2.0.1403

Cause



There were many different causes for the fixes in this hotfix. Some of the issues were simply speeding up the way SVS handled a few things while others required additions to the code.


Solution



To upgrade to SVS 2.0 Hotfix 24102 (2.0.1403), download the attached file on the right side of the screen.  Unzip the file and run the installer for either the agent (if using stand-alone SVS) or install the Solution (for Notification Server).

To see what was addressed in the previous relese (SVS 2.0 SP1) please read the release notes here:  http://kb.altiris.com/article.asp?article=23742&p=3 

These notes provide a list of fixes that have been provided and installation instructions which also apply to this build of the product.

Attachments

KB24102.zip (4 MBytes)

Legacy ID



24102


Article URL http://www.symantec.com/docs/TECH14412


Terms of use for this information are found in Legal Notices