VOM: Error V-338-1-2039 Time skew check failed when trying to add Managed Host (MH) to Central Management Server (CMS).

Article:TECH156206  |  Created: 2011-03-22  |  Updated: 2011-04-15  |  Article URL http://www.symantec.com/docs/TECH156206
Article Type
Technical Solution


Environment

Issue



Unable to add Managed Host (MH) to Central Management Server (CMS) in Veritas Operations Manager (VOM).


Error



VOM: Error V-338-1-2039 <https://vos.symantec.com/ecls/umi/V-338-1-2039>  Time skew check failed.


Environment



VOM 3.1


Cause



VOM requires that the time skew between MH and CMS is no more than 90 minutes.  How the sync is done is irrelevant.


Solution



1. Update time on MH and CMS to remove the time skew.

Or

1. Configure NTP to sync time. 




Article URL http://www.symantec.com/docs/TECH156206


Terms of use for this information are found in Legal Notices