BESR and DS are conflicting on the BCD file when each solution creates an automation folder

Article:TECH156746  |  Created: 2011-03-28  |  Updated: 2011-03-29  |  Article URL http://www.symantec.com/docs/TECH156746
Article Type
Technical Solution

Product(s)

Environment

Problem



DS 7.1 automation folders and BESR Lightout cannot be installed together on the same system


Error



Either the DS automation folder or BESR lights out will work depending on the order of the install but not both.


Environment



DS 7.1 all builds and BESR 9.0 +


Cause



Deployment Solution automation folders and BESR Lights out both update the BCD file for their specific needs. Unfortunately, they completely over write the file instead of simply adding additional entries. Because neither product is aware of the changes the other makes to the BCD files both products overwrites the others changes.


Solution



This issue is currently being investigated by the Symantec Development team.




Article URL http://www.symantec.com/docs/TECH156746