Hyper-V or AVVI GRT restores from duplicated set on tape fails with '0xe0000f0c - An error occurred when attempting to initialize encryption for job' when software encryption is enabled

Article:TECH159382  |  Created: 2011-05-04  |  Updated: 2013-03-11  |  Article URL http://www.symantec.com/docs/TECH159382
NOTE: If you are experiencing this particular known issue, we recommend that you Subscribe to receive email notification each time this article is updated. Subscribers will be the first to learn about any releases, status changes, workarounds or decisions made.
Article Type
Technical Solution


Subject

Issue



Unable to perform Granular Recovery Technology (GRT) restores from a duplicated set on tape when the duplicate job has software encryption enabled. This only occurs when the following are true:

  1. Any / All duplicate GRT enabled backup sets with Software Encryption 
  2. The backup was done using the Microsoft Hyper-V agent or the Agent for VMware Virtual Infrastructure (AVVI)

Error



An error occurred when attempting to initialize encryption for job.

Final error: 0xe0000f0c - An error occurred when attempting to initialize
encryption for job.
Final error category: Job Errors

An error occurred when attempting to initialize encryption for job.
V-79-57344-3852 - An error occurred when attempting to initialize encryption for
job.

V-79-57344-3852 - An error occurred when attempting to initialize encryption for job.
Connection to the restore target has been lost.  Operation canceled.


Environment



Windows 2008 R2
Microsoft Hyper-V


Solution



The current workaround is to re-duplicate the set on tape back to disk and then attach the VHD file (found in the IMG folder following the duplicate-to-disk job) using Windows Disk Management. The required data can then be copied from this volume.

Symantec Corporation has acknowledged that the above-mentioned issue is present in the current version(s) of the product(s) mentioned at the end of this article. Symantec Corporation is committed to product quality and satisfied customers.

There are no plans to address this issue by way of a patch or hotfix in the current or previous versions of the software at the present time. However, the issue is currently scheduled to be addressed in the next major revision of the product. Please be sure to refer back to this document periodically as any changes to the status of the defect will be reflected here.  Please note that Symantec Corporation reserves the right to remove any fix from the targeted release if it does not pass quality assurance tests.  Symantec's plans are subject to change and any action taken by you based on the above information or your reliance upon the above information is made at your own risk.

Please contact your Symantec Sales representative or the Symantec Sales group for upgrade information including upgrade eligibility to the release containing the resolution for this issue.  For information on how to contact Symantec Sales, please see http://www.symantec.com.


Supplemental Materials

SourceETrack
Value2365494
Description

Hyper-V/AVVI: Unable to do a GRT restore from duplicated set on tape when software encryption is enabled.


SourceUMI
ValueV-79-57344-3852
Description

An error occurred when attempting to initialize encryption for job.



Article URL http://www.symantec.com/docs/TECH159382


Terms of use for this information are found in Legal Notices