SEP Integration Component 7.1 Sp1 - Antivirus Inventory does not detect F-Secure Antivirus for Workstations.

Article:TECH165127  |  Created: 2011-07-21  |  Updated: 2011-07-21  |  Article URL http://www.symantec.com/docs/TECH165127
Article Type
Technical Solution


Issue



The SEP IC Antivirus Inventory does not detect F-Secure Antivirus for Workstations.


Environment



 SEP Integration Component 7.1 Sp1

Symantec Management Platform 7.1 Sp1

F-Secure Antivirus for Workstations 9.x


Cause



 KNOWN ISSUE


Solution



The issue has been reported to Symantec engineering for further investigation.

The following work around is provided at your responsibility to make a backup of each file being modified:

1. On the Symantec Management Platform Server edit the following files with Notepad:

?:\Program Files\Altiris\Notification Server\NSCap\bin\Win32\X86\Symantec Endpoint Protection\AvInventory\AVInventory.xml

?:\Program Files\Altiris\Notification Server\NSCap\bin\Win64\x64\Symantec Endpoint Protection\AvInventory\AVInventory.xml

2. Search for the line "F-Secure Anti-Virus for Workstations".

3. Edit the line to match the following:

<antiVirus name="F-Secure" searchString="F-Secure Anti-Virus for Workstations" searchPath="HKLM\SOFTWARE\Data Fellows\F-Secure\F-Secure GUI\PUB" value="ProductName">

4. Save the files (Win32 and Win64) and schedule the Antivirus Inventory.




Article URL http://www.symantec.com/docs/TECH165127


Terms of use for this information are found in Legal Notices