SMP Inventory for Unix unable to gather memory informaton from Solaris x86 computers
| Article:TECH165348 | | | Created: 2011-07-22 | | | Updated: 2011-07-22 | | | Article URL http://www.symantec.com/docs/TECH165348 |
Problem
SMP Inventory for Unix unable to gather memory informaton from Solaris x86 computers
Error
Memory information will be missing from reports, resource manager, etc. for certain solaris computers. Debug or Info level logging returns the following information regarding missing FRU ID data:
NOTE 2011-04-20 14:46:56.464 27074 38 INV-Session > Executing script Altiris_HW_PhysicalMemory-Solaris.sh...
NOTE 2011-04-20 14:46:56.465 27074 38 INV-LocalConnection > Executing shell script...
NOTE 2011-04-20 14:46:57.119 27074 38 INV-LocalConnection > Shell script stdout:
START={8ED2D679-E9D2-4142-B082-5A1704C13FEF}
END={8ED2D679-E9D2-4142-B082-5A1704C13FEF}
NOTE 2011-04-20 14:46:57.119 27074 38 INV-LocalConnection > Shell script stderr output: This system does not provide FRU ID data
NOTE 2011-04-20 14:46:57.120 27074 38 INV-Session > data size:1
NOTE 2011-04-20 14:46:57.121 27074 38 INV-Session > Executing post-processor RetrieveLogMessages...
NOTE 2011-04-20 14:46:57.121 27074 38 INV-Session > After post-processor RetrieveLogMessages data size:1
NOTE 2011-04-20 14:46:57.122 27074 38 INV-Session > Executing post-processor FormatToCimXml...
NOTE 2011-04-20 14:46:57.123 27074 38 INV-Session > After post-processor FormatToCimXml data size:23
NOTE 2011-04-20 14:46:57.124 27074 38 INV-Cimom > Save empty class 'Altiris_HW_PhysicalMemory' to cache
Environment
Inventory Solution 7.0 and 7.1 for Unix, Linux and Macintosh
Cause
Our current research indicates that this occurs only on x86 computers installed with the Solaris operating system. It does not occur on sparc machines. The FRU (Field Replacable Unit) hardware information is not available with Solaris running on x86 hardware. Research is on-going.
Solution
Alternative methods of gathering memory information is being researched. Custom inventory is a viable alternative until an update is released that resolves this issue.
|
|
Article URL http://www.symantec.com/docs/TECH165348
Terms of use for this information are found in Legal Notices









Thank you.