The Enterprise Vault (EV) File System Archiving (FSA) FileScreenFilter driver may cause cluster failover to hang.

Article:TECH167472  |  Created: 2011-08-18  |  Updated: 2014-12-08  |  Article URL http://www.symantec.com/docs/TECH167472
NOTE: If you are experiencing this particular known issue, we recommend that you Subscribe to receive email notification each time this article is updated. Subscribers will be the first to learn about any releases, status changes, workarounds or decisions made.
Article Type
Technical Solution


Issue



An issue with the FileScreenFilter.sys driver may cause the cluster failover to hang and a reboot of the node will be required. 


Cause



This issue may be caused by the filter scanning the \System Volume Information


Solution



This issue has been addressed as part of the following releases:


Enterprise Vault 9.0.4
http://www.symantec.com/docs/TECH147785

Enterprise Vault 10.0.1
http://www.symantec.com/docs/TECH147787


Supplemental Materials

SourceETrack
Value2479174
Description

MSCS cluster failover hang caused by filescreenfilter.sys




Article URL http://www.symantec.com/docs/TECH167472