KNOWN ISSUE: Check HTTP connection fails for non-Administrators

Article:TECH16885  |  Created: 2006-08-22  |  Updated: 2008-07-02  |  Article URL http://www.symantec.com/docs/TECH16885
NOTE: If you are experiencing this particular known issue, we recommend that you Subscribe to receive email notification each time this article is updated. Subscribers will be the first to learn about any releases, status changes, workarounds or decisions made.
Article Type
Technical Solution


Issue



The Check HTTP Connection action always returns a failure code, indicating that the web page is not available, when the .exe is run as a non-admin user.

Environment



Wise Installation System 9.02
Wise Installation Studio 7.x
Wise Package Studio 7.X

Cause



When using the Check HTTP Connection action, a temp file is written to the root of the C drive. A user that is not an administrator, does not have access to write to this location.


Solution



There is no resolution or workaround at this time. Symantec is working towards a resolution and will update this article when a resolution is reached. Subscribe to this article if you would like to receive any updates.

Supplemental Materials

SourceDEFECT
ValueLB 53342
DescriptionLogged in Littlebuggy (Altiris - Lindon, Plymouth) database

Legacy ID



26002