HTTP Error 500.24 – Internal Server Error An ASP .NET settings has been detected that does not apply in Integrated manager pipeline method.
| Article:TECH175945 | | | Created: 2011-12-01 | | | Updated: 2011-12-01 | | | Article URL http://www.symantec.com/docs/TECH175945 |
Problem
Unable to browse the Symantec Endpoint Encryption webserver from the IIS and unable to create framework package from the SEEM server.
Error
HTTP Error 500.24 – Internal Server Error An ASP .NET settings has been detected that does not apply in Integrated manager pipeline method.
Cause
For an overview of the request processing pipeline in Integrated mode in IIS 7.0, see ASP.NET Application Life Cycle Overview for IIS 7.0. When you use IIS 7.0, you can run applications in Classic mode and Integrated mode side-by-side on the same server. Both Classic and Integrated mode support the .NET Framework version 2.0 and later releases. The .NET Framework version 1.1 is supported in Classic mode only. For more information about how to upgrade from earlier versions of IIS to IIS 7.0, see Upgrading ASP.NET Applications to IIS 7.0: Differences between IIS 7.0 Integrated Mode and Classic mode.
Solution
1. In the IIS under Application Pools, double click on SymantecEndpointEncryption
2. Change the Managed Pipelinemode to Classic.
3. Restart the IIS admin services
4. Try to browse the page.
|
|
Article URL http://www.symantec.com/docs/TECH175945
Terms of use for this information are found in Legal Notices









Thank you.