Unable to update Compliance Accelerator Customer or Discovery Accelerator Custodian DB: Event ID 64 Cause: String or binary data would be truncated when upgrading to Compliance Accelerator or Discovery Accelerator 9 SP3 or 10 SP1
| Article:TECH178394 | | | Created: 2012-01-06 | | | Updated: 2012-06-20 | | | Article URL http://www.symantec.com/docs/TECH178394 |
Problem
Unable to complete upgrade on the Customer or Custodian database causing Discovery Accelerator to be unusable for searching.
Error
EVENT ID: 64
APP ATM - Error upgrading a Customer.
Install Thread - worker thread (0)
Cause: String or binary data would be truncated.
Cause
The tblAddressUser table in the Compliance Accelerator (CA) Customer or Discovery Accelerator (DA) Custodian Manager database contains a column that contains display names. When a display name exists that is longer than 100 characters, the above error is thrown during the upgrade attempt as the column is set to only contain a maximum of 100 characters.
Solution
This issue has been addressed in the following release:
Enterprise Vault 9.0.4
http://www.symantec.com/docs/TECH147785
Symantec Corporation has acknowledged that the above-mentioned issue is present in the current version(s) of the product(s) mentioned at the end of this article. Symantec Corporation is committed to product quality and satisfied customers.
Please be sure to refer back to this document periodically as any changes to the status of the issue will be reflected here.
|
|
| Source | ETrack |
| Value | 2652691 |
| Description | Unable to update Custodian DB: Event ID 64 Cause: String or binary data would be truncated. |
| Source | Event ID |
| Value | 64 |
| Description | APP ATM - Error upgrading a Customer. |
| Source | UMI |
| Value | V-437-64 |
| Description | APP ATM - Error upgrading a Customer. |
Article URL http://www.symantec.com/docs/TECH178394