VCS 5.0MP1_SOLARIS10: GAB: Port h halting system due to client process failure.

Article:TECH183589  |  Created: 2012-03-12  |  Updated: 2012-03-12  |  Article URL http://www.symantec.com/docs/TECH183589
Article Type
Technical Solution

Product(s)

Environment

Issue



VCS 5.0MP1_SOLARIS10: GAB: Port h halting system due to client process failure.


Error



STACK of had's Kernel thread that hang the system

-----------------------------------------------------------------

genunix:cv_wait+0x38()
genunix:holdlwps+0xbc()
genunix:cfork+0x40()
unix:syscall_trap32+0xcc()

 


Solution



It's a know issue. Please see the Technote 57527. It's recommended to upgrade VCS 5.0MP1 to VCS 5.0MP3. Please refer to its Release Notes.




Article URL http://www.symantec.com/docs/TECH183589