Error regarding database field when integrating RAM with CCS "Warning - The source fields from the sample file path do not match the system source fields. data import job will fail."

Article:TECH184662  |  Created: 2012-03-23  |  Updated: 2012-03-23  |  Article URL http://www.symantec.com/docs/TECH184662
Article Type
Technical Solution


Issue



An error is encountered when attempting to integrate RAM with CCS


Error



"Warning - The source fields from the sample file path do not match the system source fields.  data import job will fail."


Cause



An additional field/view is required for RAM integration. 


Solution



Install either the 10.50.166.10101 Hotfix to add the view RAM.CCSEvidence to the CSM.Evidence db, or apply RAM 2011-3 PCU

The 10.50.166.10101 Hotfix is integrated in RAM 2011-3 PCU


Supplemental Materials

Description

www.symantec.com/docs/TECH163010




Article URL http://www.symantec.com/docs/TECH184662


Terms of use for this information are found in Legal Notices