CommandCentral Storage fails to discover Brocade Access Gateway switches.

Article:TECH188717  |  Created: 2012-05-14  |  Updated: 2012-05-14  |  Article URL http://www.symantec.com/docs/TECH188717
Article Type
Technical Solution


Environment

Issue



CommandCentral Storage fails to discover Brocade Access Gateway switches.


Error



FCMGMTExp: Failed to get Vendor and MIB type for the switch . Error:0. Switch vendor may be unknown or switch may not be supporting FCMGMT MIB or network may be too slow


Cause



CCS may be configured to discover Brocade Access Gateway switches directly.  This is not a supported configuration, discovery must occur through a Brocade SMI-S agent.


Solution



See the CommandCentral Storage Hardware Software Configuration Guide for step-by-step instructions on how to setup discovery through SMI-S.  The guide is downloadable from https://sort.symantec.com/documents