A firmware update is available for NetBackup 5000, 5020, and 5200 Appliances which resolves an issue where the failure of a single disk could cause a cascading failure on multiple (good) drives.

Article:TECH192604  |  Created: 2012-07-09  |  Updated: 2013-02-19  |  Article URL http://www.symantec.com/docs/TECH192604
NOTE: If you are experiencing this particular known issue, we recommend that you Subscribe to receive email notification each time this article is updated. Subscribers will be the first to learn about any releases, status changes, workarounds or decisions made.
Article Type
Technical Solution

Product(s)

Issue



Document History:
July 9, 2012: Originally published
February 19, 2013: Updated with newer firmware revision and Etrack references

RAID controller firmware in NetBackup 5000, 5020 and 5200 Appliances shipped prior to July 2012 must be updated to prevent a condition where the failure of a single disk could cause a cascading failure on multiple (good) drives. If multiple drives appear to fail it can lead to a forced offlining of the RAID Virtual Disk and other unexpected results, up to and including data loss.


Environment



The following NetBackup Appliances have the potential to be affected: 

  • 5000
  • 5020
  • 5200

Note: NetBackup 5220 Appliances are not affected by this issue.

How to Determine if a 5000 or 5020 Appliance is Affected:
To check firmware version, log into the sysadmin account and issue these commands:

  • admin
  • su
  • /opt/MegaRAID/MegaCli/MegaCli64 -adpallinfo -a0 | grep "FW Version"

Example:
Entering root view, following commands are available...

admin     --Administrator user account
history   --Display the current session's command line history
logout    --Logout the CLI session
network   --Network Management
nodeinfo  --Show storage pool nodes info
PDCLI     --PureDisk Command Line Interface Management
FC        --Fibre Channel management
PureDisk  --PureDisk Management
scsp      --Symantec Critical System Protection
storage   --Storage Management
system    --System Management
vzone     --Virtual Zone Management
IPMI      --IPMI Management
          
example5020-01> admin
Entering admin view, following commands are available...

exit      --Return to root view
history   --Display the current session's command line history
logout    --Logout the CLI session
nodeinfo  --Show storage pool nodes info
password  --Change user password
su        --Change to root access

example5020-01.admin> su
example5020-01:~ # /opt/MegaRAID/MegaCli/MegaCli64 -adpallinfo -a0 | grep "FW Version"
FW Version         : 1.40.322-1445
 

Note: Enter logout twice to log out.

If the value of the last four digits is less than 1650, then the Appliance has the potential to be affected.  A firmware upgrade should be undertaken as soon as possible.

 

How to Determine if a 5200 Appliance is Affected:
To check firmware version, log into the CLISH menu and issue these commands:

  • Support
  • MegaCli Run
  • -adpallinfo -a0 | grep "FW Version"

Example:
Last login: Mon Jul  9 16:14:56 2012 from example.symantec.com

Appliance  Media server appliance configuration.
Exit       Logout and exit from the current shell.
Manage     Manage NetBackup Appliance.
Monitor    Monitor NetBackup Appliance Activities.
Network    Network Administration.
Reports    Examine the running and historical state of the host.
Settings   Change NetBackup Appliance Settings.
Shell      Shell operations.
Support    NetBackup Support.

nbapp.Main_Menu> Support
Entering NetBackup Support view...
Beacon          Flashes or stops flashing the lights.
DataCollect     Gather device logs.
Disk            Gather disk information.
Errors          Display NetBackup errors.
Exit            Logout and exit from the current shell.
FactoryReset    Reset this appliance to factory defaults.
Logs            Set level, share, unshare, view, and upload debug logs.
Maintenance     Launch maintenance shell.
MegaCli         Use MegaCli utility to manage RAID volumes.
Messages        Display the messages file.
NBDNA           Network traces with NBDNA tool (Select Create or Remove).
NBSU            Manage NetBackup support data files (Select Create or Remove).
Processes       Show/control NetBackup and Admin Console processes.
Reboot          Reboot the system.
RecoverStorage  Test the current status of various appliance components.
Return          Return to the previous menu.
Shell           Shell operations.
Show            Display information.
Shutdown        Power off the system.
Test            Test the current status of various appliance components.

nbapp.Support> MegaCli Run
Please enter options:
MegaCli64 -adpallinfo -a0 | grep "FW Version"
FW Version         : 1.40.322-1445

Note: Enter q to exit.

If the value of the last four digits is less than 1650, then the Appliance has the potential to be affected.  A firmware upgrade should be undertaken as soon as possible.


Solution



NetBackup 50x0 Appliances:
Please contact Symantec technical support, referencing this document and Etrack 3030451 to obtain replacement firmware and instructions for installation.

This firmware upgrade will also be included in the following release update:

  • NetBackup Appliances 50x0 D1.4.4 

NetBackup 5200 Appliances
This firmware upgrade will also be included in the following release update:

  • NetBackup Appliances 52x0 N2.5.2

If the command above is run on a NetBackup 5200 Appliance and it is found that the firmware needs to be upgraded, please contact Symantec technical support, referencing this document and Etrack 3056206 to obtain replacement firmware and instructions for installation.

When verisons 1.4.4 and 2.5.2 are release, please access the following link for download and README information:
 http://www.symantec.com/business/support/index?page=landing&key=58991

Best Practices:
Symantec strongly recommends the following best practices:
1. Always perform a full DR backup prior to making any changes to your environment.
2. Always make sure that your environment is running the latest version and patch level.
3. Perform periodic "test" restores.
4. Subscribe to technical articles.

How to Subscribe to Email Notification:
Directly to this Article:
Subscribe to this article by clicking on the Subscribe via email link on this page to receive notification if this article is updated.

Software Alerts:
If you have not received information about this TechNote from the Symantec Email Notification Service as a Software Alert, you may subscribe via email and/or RSS using the links provided at the following page:
 http://www.symantec.com/business/support/index?page=content&key=58991&channel=ALERTS


Supplemental Materials

SourceETrack
Value3056206
Description

upgrade RAID controller firmware to 11.0.1-0048_1078_FW_29s_Delay_APP-1.40.342-1650.rom