All client machines show as 'Not Reporting' in the Symantec System Recovery Management Solution (SSR-MS) console.

Article:TECH193284  |  Created: 2012-07-19  |  Updated: 2013-04-18  |  Article URL http://www.symantec.com/docs/TECH193284
Article Type
Technical Solution


Issue



All client machines show a status of 'Not Reporting' inside the Symantec System Recovery Management Solution (SSR-MS) console. All client communication is working and scheduled backups are running.

This has been seen (but may not be limited to) following a re-installation of the Symantec Management Platform (SMP) and SSR-MS. The original database was re-attached to SMP following the new install.


Solution



Edit the CoreSettings file using notepad. CoreSettings is found in \ProgramData\Symantec\SMP\Settings.

Change the value of "EnableNSEventLog" from false to true and save the file.

Once the above has been done, restart the 'Altiris Service' on the SMP/SSR-MS server. Client machines will then start showing the correct status when they next send their configuration update (by default, this is set to once an hour).




Article URL http://www.symantec.com/docs/TECH193284


Terms of use for this information are found in Legal Notices