Machine freezes after installing SEEFD 8.2.0 MP2 HF3 on the PBA screen.

Article:TECH195846  |  Created: 2012-08-29  |  Updated: 2012-08-30  |  Article URL http://www.symantec.com/docs/TECH195846
Article Type
Technical Solution


Issue



After installing the SEEFD the machine freezes at the PBA screen.

Client machine :  Model - DTRINC-DT362XL


Environment



SEE version : SEE FD 8.2 MP2 HF3
Make & Model -: DTRINC
System Manufacturer DTRINC
System Model DT362XL
 


Cause



Issue - Client machine : model - DTRINC-DT362XL does not booting up after
installing the client package, unable to log on.
 


Solution



This issue is known to Symantec and the fix is expected in the upcoming release. The current version of SEEFD is 8.2.1 MP2




Article URL http://www.symantec.com/docs/TECH195846


Terms of use for this information are found in Legal Notices