Symantec Endpoint Protection 12.1 RU2 Client Fails to Install Completely on Windows Embedded for Point of Service

Article:TECH199992  |  Created: 2012-11-21  |  Updated: 2014-06-05  |  Article URL http://www.symantec.com/docs/TECH199992
Article Type
Technical Solution


Issue



The installation of Symantec Endpoint Protection 12.1 RU2 (SEP) client onto some WEPOS machines seems to progress without error, but after the computer, kiosk or other embedded device reboots there will be a notice in the SEP client GUI that the firewall is malfunctioning. 

Attempting to repair the install from Control Panel will result in a pop-up message, "Fatal error during installation."


Error



The teeferInstall.log file shows the following error: InstallFirewall failed second attempt: 0x800704c7

Running SymHelp afterwards will detect:

Error Service EraserUtilRebootDrv is not installed. 
Error Service eeCtrl is not installed.
Error Service Teefer2 is currently stopped.

(or, of MinimizeFootprint reg key was not altered before install:)

Error Service EraserUtilRebootDrv is not installed. 
Error Service eeCtrl is not installed.
Error Service Teefer2 is currently stopped.

 


Environment



Symantec Endpoint Protection 12.1 RU2


Solution



The following steps will enable the SEP 12.1 RU2 client to install successfully and completely:

 

1. Modify the "MinimizeFootprint" registry key: 

HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Setup] "MinimizeFootprint"=dword:00000001

Delete or rename "MinimizeFootprint" value from registry and reboot, then install SEP.

2. Install SEP 12.1 RU2 with the Network Threat Protection (Firewall) component only. After the client computer is rebooted, the teefer2 will be a stopped state:  

Teefer2 Service Teefer2 LocalSystem Manual Stopped 1077 Kernel Driver     Symantec Corporation Symantec CMC Firewall 100.0.814.814 100.0.814.814 Symantec CMC Firewall Teefer2 C:\Windows\system32\drivers teefer.sys

The SEP GUI will display "Firewall is malfunctioning.  Firewall is not functioning correctly.  Your protection definitions may be damaged or your product installation may be corrupt."  
 
These initial errors are expected.

 

3. Manually install teefer2: In connection properties (for example : "Local Area Connection Properties"), select "Install"->"Service"->"Add", then select the [SEP CD]\Program Files\Symantec\Name\Version\Bin\ TeeferXP\teefer.inf file.

4. Run "smc -stop" and "smc -start" to restart smc. (Or, reboot the client)

5.  From Control Panel, modify Symantec Endpoint Protection to add AntiVirus and any other components desired (PTP, etc) 

6.  Recover "MinimizeFootprint" value after installation is finished successfully.

 

After this procedure is complete, all of SEP 12.1 RU2 should be in a running state, with no error displayed in the GUI.

 

 


Supplemental Materials

SourceETrack
Value3003276


Article URL http://www.symantec.com/docs/TECH199992


Terms of use for this information are found in Legal Notices