Patch-002 Bare Metal Restore 3.2.1 for TSM

Article:TECH21169  |  Created: 2002-01-15  |  Updated: 2004-01-08  |  Article URL http://www.symantec.com/docs/TECH21169
Article Type
Technical Solution


Environment

Problem



Patch-002 Bare Metal Restore 3.2.1 for TSM

Solution



Patch ID: 3.2.1-002
Targeted Versions: Bare Metal Restore 3.2.1 for TSM
Platforms: AIX, HP-UX, Solaris, Windows NT, Windows 2000
Problems and Defects Resolved:
CaseID Defect Abstract
------------ ------ ----------------------------------------------------------
10840 bmrrst restores wrong bmrcli.dat.
10909 TCP/IP paramaters bound to wrong inteface.
11400 rootvg restoration of AIX client failed to locate
physical volume.
11509 Drive mapping out of order after restore.
11573 SRT creation failed because of a space in SRT.schema.
11579 Non-rootvg created but not automatically imported on HP.
11583 Remove BMRDRVPARAMS except slotnumber from unattend.txt.
11594 Windows: Dynamic disks not identified in bmrmap.
11596 TSM not processing "saveconfig" as a prescheduled command.
11640 The DOS GUI should be exited before running winnt command.
11641 txtsetup.oem should include all .sys files.
11644 Enhance bmrc -v to show patch information.
11703 TESTHPTSMPATCH:can't replace bmrd after applying patch2
over P1
Problems and Defects Resolved in patch 3.2.1-001:
CaseID Defect Abstract
------------ ------ ----------------------------------------------------------
N/A 10586 Restore on French Windows systems break because
"Administrator" is hard-coded.
N/A 10823 Drive labels are not set correctly after a Windows 2000
dissimilar disk active directory restore.
180-671-338 10850 AIX restore mirror quorum not set correctly after restore.
180-671-376 10851 BMR does not handle bootlist in an AIX mirrored
environment.
100-259-861 11080 If vg00 does not exist on HP systems, createBI will fail.
100-259-861 11221 Systems with multiple mass storage driver registry entries
100-257-861 must be processed correctly.
100-255-859 11251 SrcDir may be set incorrectly in oemsetup.inf.
100-257-000 11313 Booting from boot floppy hangs during format of repair
partition.
N/A 11432 Windows systems with type 15 partitions are not processed
correctly.
150-250-881 11440 Re-creation of HP filesystems with largefile settings
fails.
180-671-455 11505 The incorrect cpqarray.sys file is used when restoring
Compaq systems running Windows NT.
180-671-456 11508 Booting Windows systems with large memory modules take
long because "testmem:off" is not set in himem.sys.
N/A 11526 Solaris dissimilar disk restore fails when the number of
cylinders on the target disk is less than the original
disk.
N/A 11534 bmrsavcfg.exe cannot find .INF files on Windows NT.
100-260-241 11543 SAMBA filesets not available in when installing on
AIX 5.1 systems.
100-259-861 11561 BMR assumes root volume is vg00 on HP systems.
N/A 11562 Media boot cannot determine the OS level of an AIX SRT.
N/A 11575 Bad messages during bmrcreatesrt -a nt.
Files affected:
BMR servers:
$BMRDIR/bmrmain.bmr
$BMRDIR/setupserver.bmr
$BMRDIR/SRT.schema
$BMRDIR/2000/srtfiles
$BMRDIR/aix/bmr_mkboot.bmr
$BMRDIR/aix/bmr_mkfs.bmr
$BMRDIR/aix/bmrc
$BMRDIR/aix/bmrd
$BMRDIR/aix/bmrgui.exe
$BMRDIR/aix/bmrmkcdimage.bmr
$BMRDIR/hp/bcreateBI.bmr
$BMRDIR/hp/bmr_mkboot.bmr
$BMRDIR/hp/bmr_mkfs.bmr
$BMRDIR/hp/bmrc
$BMRDIR/hp/bmrd
$BMRDIR/hp/bmrgui.exe
$BMRDIR/hp/bmrsavecfg.bmr
$BMRDIR/nt/bcreateSRT.bmr
$BMRDIR/nt/srtfiles
$BMRDIR/sol/bmr_mkfs.bmr
$BMRDIR/sol/bmrc
$BMRDIR/sol/bmrd
$BMRDIR/sol/bmrgui.exe
AIX clients:
$BMRDIR/aix/bmrc
HP-UX clients:
$BMRDIR/hp/bmrc
$BMRDIR/hp/bmrsavecfg.bmr
Solaris clients:
$BMRDIR/sol/bmrc
Windows 2000 clients:
%BMRDIR%\bmrc.exe
%BMRDIR%\bmrsavecfg.exe
%BMRDIR%\bmrsetupclient.exe
%BMRDIR%\bmrutils.lib
%BMRDIR%\mediafi
Windows NT clients:
%BMRDIR%\bmrc.exe
%BMRDIR%\bmrsetupclient.exe
%BMRDIR%\bmrsvcfg.exe
%BMRDIR%\bmrutils.lib
%BMRDIR%\mediafi
Installation Instructions:
On AIX, HP-UX and Solaris platforms:
1. Download the patch file from
http://support.veritas.com/menu_ddProduct_BMRTSM.htm
2. To apply the downloaded patch to a BMR server machine execute:
$BMRDIR/bmrpatchserver -f <patch_file>
where patch_file is the location of the downloaded patch file.
3. To apply the downloaded patch to a BMR client machine execute:
$BMRDIR/bmrpatchclient -f <patch_file>
where patch_file is the location of the downloaded patch file.
Known Issues with AIX, HP-UX and Solaris:
1. When applying patch 3.2.1-001 on a Bare Metal Restore server
before bmrsetupserver has been executed, the message:
"Could not restart BMR server daemon."
will be displayed. This is an erroneous error message in
this situation and the application of the patch was successful.
2. After 3.2.1-001 has been applied on Solaris BMR servers, a
message may be logged in /var/bmr/log/bmrd.err indicating
libucb.so could not be found. This error is a result of a BMR
packaging prerequisite and not associated with patch 3.2.1-001.
Installation of package SUNWscpu onto the Solaris machine will
resolve the error.
3. The following steps will need to be applied to HP-UX systems with
non-root volume groups following a restore to import and activate
the non-root volume groups:
a. /usr/bin/mv /etc/lvmtab /etc/lvmtab.bak
b. /sbin/vgscan -v
c. For each non-root volume group:
/sbin/vgimport -v /dev/<vg_name> /dev/dsk/<dsk_name>
d. /sbin/vgchange -a y
e. Mount all missing filesystems using /usr/sbin/mount, or reboot
the system.
#################################################################
WARNING: While applying the 3.2.1-002 on HP platforms you may see
the following error message:
mv: hp/bmrd: cannot write: Text file busy
You may safely ignore this message.
On AIX platforms you may be asked the following question:
override mode 755 on aix/bmrd?
You should answer yes to this question.
#################################################################
On Windows NT and Windows 2000:
1. Download the patch file from
http://support.veritas.com/menu_ddProduct_BMRTSM.htm
2. To apply the downloaded patch run the bmrpatch utility from
%BMRDIR%.
3. In the first screen displayed, type in the location of the patch
file in the patch file text edit box or select the patch file by
using the "Browse" dialog. Click "Next".
4. In the subsequent screen click "Next" to begin application of the
patch.
5. After patch application is completed, the "Finish" button will be
enabled. Click "Finish" to exit the patch utility.
Known Issues with Windows NT and Windows 2000:
1. After patch 3.2.1-001 has been applied on Windows NT or Windows
2000 clients, boot floppies will need to be re-created prior
to initiating restore operations


Attachments

BMR-3.2.1-002forTSM_249047.tar.Z (8.3 MBytes)

Legacy ID



249047


Article URL http://www.symantec.com/docs/TECH21169


Terms of use for this information are found in Legal Notices