KNOWN ISSUE: WISESCRIPT: Check HTTP Connection causes the wisescript to error if MSVCR71.dll is not on the machine

Article:TECH23005  |  Created: 2006-10-13  |  Updated: 2008-07-10  |  Article URL http://www.symantec.com/docs/TECH23005
NOTE: If you are experiencing this particular known issue, we recommend that you Subscribe to receive email notification each time this article is updated. Subscribers will be the first to learn about any releases, status changes, workarounds or decisions made.
Article Type
Technical Solution


Issue



When running a wisescript .EXE that contains either a Check HTTP Connection Action, or a Copy Local File action whose source is a URL, if you do not have the file MSVCR71.dll on the destination machine the following error occurs:
'The dynamic link library MSVCR71.dll could not be found in the specified path' 


Environment



 


Solution



Workaround: Add an Install File action that installs MSVCR71.dll before the Check HTTP Connection or Copy Local File action.

Supplemental Materials

SourceDEFECT
ValueLB 53850
DescriptionLogged in Littlebuggy (Altiris - Lindon, Plymouth) database

Legacy ID



28522


Article URL http://www.symantec.com/docs/TECH23005


Terms of use for this information are found in Legal Notices