Error "Robotic library transport element full error"

Article:TECH23177  |  Created: 2002-01-04  |  Updated: 2014-01-28  |  Article URL http://www.symantec.com/docs/TECH23177
Article Type
Technical Solution

Product(s)

Issue



Event ID 58053: "Robotic library transport element full error. The robotic library has reported a transport element full error condition. This is typically caused by media being left in the robotic arm during an incomplete shutdown of the library hardware. The library and drive states have been set to offline" is reported in the Application Log.


Error



Event ID: 58053
Source:Backup Exec
Type:Error
Description: Backup Exec Alert: Device Error
(Server: "%server%") (Job: "Weekly Tape Backup - (Full)" Robotic library transport element full error.

The robotic library has reported a destination element full error condition. This is typically caused by tryig to mount media into a drive that already contains media.

The drive state has been set to offline. Please attend to this condition.

Error in BE 2012:

V-275-548 Robotic library destination element full error.

The robotic library has reported a destination element full error condition. This is typically caused by trying to mount media into a drive that already contains media. The drive state has been set to offline. Please attend to this condition.


Cause



The alert is reported when the robotic library tries to move media from a robotic library drive to a slot and the slot already contains media. The robotic library state has been set to offline. 


Solution



Move the media to another slot and then re-inventory (scan) the robotic library. In case if the issue persist, try the following steps:
  • Install the latest Symantec driver for the tape drive.
  • Power cycle the Robotic library, autoloader or tape drive, followed by Inventory job.
  • Check for hardware errors or conditions, if required contact the hardware vendor.
 

Supplemental Materials

SourceEvent ID
Value58053
Description

Robotic library transport element full error. The robotic library has reported a transport element full error condition. hided the server name from images in cause section.


SourceUMI
ValueV-275-548
Description

Robotic library destination element full error.



Legacy ID



252388


Article URL http://www.symantec.com/docs/TECH23177