Robot inventory fails with "Unable to Initialize robot (204)" for the Quantum ATL Superloader, also marketed as Tandberg 3520L Superloader, Compaq 1280 Superloader and HP StorageWorks 1/16 Superloader, when both magazines are not loaded.

Article:TECH23961  |  Created: 2003-01-03  |  Updated: 2013-10-23  |  Article URL http://www.symantec.com/docs/TECH23961
Article Type
Technical Solution

Product(s)

Environment

Issue



Robot inventory fails with "Unable to Initialize robot (204)" for the Quantum ATL Superloader, also marketed as Tandberg 3520L Superloader, Compaq 1280 Superloader and HP StorageWorks 1/16 Superloader, when both magazines are not loaded.

Error



Unable to Initialize robot (204)

Solution



Robot inventory fails with the error - "Unable to Initialize robot (204)" when both magazines are not loaded.
The robot is capable of holding one or two magazines, each magazine holding eight slots. When VERITAS NetBackup (tm) issues an inventory command, the robot comes back with the first eight slots from the first magazine. The inventory fails on the ninth slot if the second magazine is not loaded and instead has a blank filler in place. Adding an empty second magazine will solve the problem temporarily.
The robot generates the following error:
Sense code = 0x3b, Code qualifier = 0x11
for slots 9 to 16 which can be verified by testing with the robtest utility after configuring the robot and drives within NetBackup device management:
C:\Program Files\VERITAS\Volmgr\bin\robtest
Configured robots with local control supporting test utilities:
TLD(2) robotic path = \\.\Changer0
Robot Selection
---------------
1) TLD 2
2) none/quit
Enter choice: 1
1
Robot selected: TLD(2) robotic path = \\.\Changer0
Invoking robotic test utility:
C:\Program Files\VERITAS\Volmgr\bin\tldtest.exe -r \\.\Changer0 -d1 Tape0
Opening \\.\Changer0
Enter tld commands (? returns help information)
s s
slot 1 (addr 256) contains Cartridge = yes
Source address = 259
Barcode = NBU001
slot 2 (addr 257) contains Cartridge = yes
Source address = 257
Barcode = NBU002
slot 3 (addr 258) contains Cartridge = no
slot 4 (addr 259) contains Cartridge = no
slot 5 (addr 260) contains Cartridge = no
slot 6 (addr 261) contains Cartridge = no
slot 7 (addr 262) contains Cartridge = no
slot 8 (addr 263) contains Cartridge = no
slot 9 (addr 264) contains Cartridge = no
Sense code = 0x3b, Code qualifier = 0x11
slot 10 (addr 265) contains Cartridge = no
Sense code = 0x3b, Code qualifier = 0x11
slot 11 (addr 266) contains Cartridge = no
Sense code = 0x3b, Code qualifier = 0x11
slot 12 (addr 267) contains Cartridge = no
Sense code = 0x3b, Code qualifier = 0x11
slot 13 (addr 268) contains Cartridge = no
Sense code = 0x3b, Code qualifier = 0x11
slot 14 (addr 269) contains Cartridge = no
Sense code = 0x3b, Code qualifier = 0x11
slot 15 (addr 270) contains Cartridge = no
Sense code = 0x3b, Code qualifier = 0x11
slot 16 (addr 271) contains Cartridge = no
Sense code = 0x3b, Code qualifier = 0x11
READ_ELEMENT_STATUS complete
<<<   Robtest output complete   >>>

Updated firmware on the robot reports extra SCSI information not available when the device was previously tested.
0x3B - ASC value (in hexadecimal)
0x11 - ASCQ value (in hexadecimal)
MEDIUM MAGAZINE NOT ACCESSIBLE - Error or exception indicated by the ASC/ASCQ pair value

The current workaround is to use an additional blank magazine in the second bay or fill it with tapes too. A permanent resolution is planned for Maintenance Pack 4 (MP4). Please use the VERITAS E-mail Notification service available at  http://maillist.support.veritas.com/subscribe.asp to keep track of future patch releases.