Altiris Deployment Server Data Manager won't start

Article:TECH40763  |  Created: 2008-10-27  |  Updated: 2012-07-28  |  Article URL http://www.symantec.com/docs/TECH40763
Article Type
Technical Solution


Issue



The Altiris Deployment Server Data Manager service won't start.  When you check the application log, you see the following error.

Only one usage of each socket address (protocol/network address/port) is normally permitted.

Environment



DS 6.9 sp1

Cause



Another process was using a necessary port for the Data Manager service.  These ports are 8080 and 1433.

Solution



Download TCPView or another port sniffing application.  Locate what process is using one of the Data Manager ports and kill that process.  In this case, it was an process called miniwinagent.exe.  Once this process was killed, the Data Manager started right up.

Legacy ID



44166


Article URL http://www.symantec.com/docs/TECH40763