KNOWN ISSUE: Unable to create new Application Monitor Policy after upgrading to Inventory SP1
| Article:TECH45443 | | | Created: 2009-09-29 | | | Updated: 2009-09-29 | | | Article URL http://www.symantec.com/docs/TECH45443 |
| NOTE: If you are experiencing this particular known issue, we recommend that you Subscribe to receive email notification each time this article is updated. Subscribers will be the first to learn about any releases, status changes, workarounds or decisions made. |
Problem
After upgrading the Inventory Solution software to SP1, the option to create a new Application Monitor Policy is no longer available.
Normally, this would be found by navigating to: Manage > Policies > Software: Then right-clicking the Application Metering and choosing New > Application Metering Policy
Environment
Inventory Solution 7.0 SP1
Solution
This is scheduled for correction in the next release of the Inventory Solution. To work around this issue: Simply clone an Existing Application Monitor Policy and customize the cloned policy with the desired new information. When this has been completed, save the policy as normal.
| Source | DEFECT |
| Value | ETK 1834159 |
| Description | Logged in Etrack (Symantec) database |
Legacy ID
49341
Article URL http://www.symantec.com/docs/TECH45443
Terms of use for this information are found in Legal Notices