Error "Error 1935" is returned when installing Remote Agent for Windows Servers on a x64 server.
| Article:TECH51184 | | | Created: 2007-01-26 | | | Updated: 2012-04-30 | | | Article URL http://www.symantec.com/docs/TECH51184 |
Problem
Error "Error 1935" is returned when installing Remote Agent for Windows Servers on a x64 server.
Error
ERROR: Error 1935. An error occurred during the installation of assembly 'Microsoft.VC80.CRT,type="win32",version="8.0.50727.762",publicKeyToken="1fc8b3b9a1e18e3b",processorArchitecture="amd64"'. Please refer to Help and Support for more information.
Solution
The above error will occur if the service "Windows Modules Installer" is disabled.
Solution:
1. Enable the "Windows Modules Installer" service
2. Ensure that the Windows Installer service is set to "Manual"
Solution:
1. Enable the "Windows Modules Installer" service
2. Ensure that the Windows Installer service is set to "Manual"
|
|
Legacy ID
287976
Article URL http://www.symantec.com/docs/TECH51184
Terms of use for this information are found in Legal Notices









Thank you.