Veritas NetBackup (tm) PureDisk Remote Office Edition 6.1 Maintenance Pack 2 (MP2) Patch 1 (P01) - Symantec Corporation PureDisk 6.1_MP2_P01_301814.tar

Article:TECH58866  |  Created: 2008-01-24  |  Updated: 2008-01-02  |  Article URL http://www.symantec.com/docs/TECH58866
Article Type
Technical Solution

Product(s)

Environment

Problem



Veritas NetBackup (tm) PureDisk Remote Office Edition 6.1 Maintenance Pack 2 (MP2) Patch 1 (P01) - Symantec Corporation PureDisk 6.1_MP2_P01_301814.tar

Solution



Name: NB_PDE_61_MP2_P01
Date: April 01, 2008

==============================================================================
This patch provides features and fixes to the Veritas NetBackup
PureDisk Remote Office Edition 6.1 software.

WARNING: When you apply this patch, all PureDisk services stop
        and start.  This can cause running jobs to abort.
==============================================================================

=================
PACK DEPENDENCIES
=================

Install PureDisk 6.1, version 6.2_MP2, before you install this patch.


=============
PRODUCT FIXES
=============

This patch contains fixes for issues described in following 3 techalerts:

- Tech Alert 300804 (http://entsupport.symantec.com/docs/300804)

   The ContentRouter can potentially have an inconsistent FingerPrint cache.
   If a 'delete segment' task gets processed during a specific period of the reload
   of the FingerPrint cache, then the FingerPrint cache can become inconsistent.
   If during this inconsistent cache state that deleted segment needs to be backed
   up again, the ContentRouter thinks it is already protected and doesn't store the
   segment again.
   (Internal reference: ET1213743, Titan: 281-274-736)

- Tech Alert 300805 (http://entsupport.symantec.com/docs/300805)

   If the PureDisk MetabaseEngine has a lot of Data Selections and/or a lot of changes
   to the Data Selections, it's possible for the pg_class table from Postgres to
   become incomplete, which can lead to dataloss.
   (Internal reference: ET1217891, Titan: 240-724-779)

- Tech Alert 300951 (http://entsupport.symantec.com/docs/300951)

   A potential for data loss has been discovered in Data Removal.
   The Data Removal Policy may erroneously delete a file version if that file
   wasn't changed for a while AND has recently been deleted from the client.
   (Internal reference: ET1224522, Titan: 230-480-516)


=====================
DOWNLOAD INSTRUCTIONS
=====================

1.  Use rcp or scp to copy the tar file, NB_PDE_61_MP2_P01_301814.tar,
   to the /root directory of the PureDisk node that hosts the storage pool authority.

2.  Log on as root to the node that hosts the storage pool authority.

3.  Type cd /root to go to the /root directory.

4.  Type the following command to verify the integrity of the patch:

       md5sum /root/NB_PDE_61_MP2_P01_301814.tar

   This command computes the md5 checksum of the patch.  The md5
   checksum of the patch must match 'a501babc93be16a5ed4593e7a047194e'.

   If you obtain a different checksum, the patch was corrupted during
   download. Try to download the patch again.

5.  Type the following command to extract the README file:

       tar -C / -xf /root/NB_PDE_61_MP2_P01_301814.tar ./README


=========================
INSTALLATION INSTRUCTIONS
=========================

1.  Make sure that no PureDisk jobs are currently running or are scheduled to be run.

2.  Log out from the Web UI.

3.  Type the following command to unpack the patch software:

       tar -C / -xf /root/NB_PDE_61_MP2_P01_301814.tar ./opt

4.  Type the following command to run and install the patch:

       /opt/pdinstall/apply-NB_PDE_61_MP2_P01.sh

   If the topology.ini file is encrypted, the software prompts you for the
   password to decrypt this file.

   The patch automatically pushes the software to all nodes in the
   storage pool and to all clients.

   At the end of a successful installation, the software prompts you to encrypt
   the topology.ini file.


Attachments

NB_PDE_61_MP2_P01_301814.tar (520 kBytes)


Legacy ID



301814


Article URL http://www.symantec.com/docs/TECH58866


Terms of use for this information are found in Legal Notices