Extra attributes appear in the Veritas Cluster Server (VCS) 5.0 Cluster Manager GUI after installing Rollup Patch 1a

Article:TECH59401  |  Created: 2008-01-09  |  Updated: 2009-01-10  |  Article URL http://www.symantec.com/docs/TECH59401
Article Type
Technical Solution


Environment

Issue



Extra attributes appear in the Veritas Cluster Server (VCS) 5.0 Cluster Manager GUI after installing Rollup Patch 1a

Solution



Symptom:
The normal Properties view seen in the VCS 5.0 GUI is shown in Figure 1.
 
Figure1.

After applying RP1a to a VCS 5.0 environment, extra attributes appear when viewing any properties in the Cluster Manager GUI, as shown in Figure 2.
 
Figure 2.

Cause:
This is caused by a syntax formatting error in one of the xml files used to build the Cluster Manager views.

Solution:
An update is available to correct the syntax error in the xml file.  To obtain this update, please click on the Download Now link below.



Attachments

RP1GUI_302583.zip (17 kBytes)

Legacy ID



302583


Article URL http://www.symantec.com/docs/TECH59401


Terms of use for this information are found in Legal Notices