BUG REPORT: When using the bp or bpadm interface on HP-UX 11.23 or 11.31 systems on Integrity (IA-64) architecture, a DATE ERROR will be returned during attempts to change dates.

Article:TECH63501  |  Created: 2008-01-23  |  Updated: 2009-01-01  |  Article URL http://www.symantec.com/docs/TECH63501
Article Type
Technical Solution


Environment

Issue



BUG REPORT: When using the bp or bpadm interface on HP-UX 11.23 or 11.31 systems on Integrity (IA-64) architecture, a DATE ERROR will be returned during attempts to change dates.

Solution



Bug: 1395328

Symptoms:  
On Integrity (IA-64) systems running HP-UX 11v2 (11.23) or 11v3 (11.31), when attempting to change the start and end date range from within the bp or bpadm menu interfaces, an error will be displayed in place of the Current Start Date field.

Example:
The following error will be returned in any area of the Backup or Restore menu where users select d) Change Date Range...

Current Start Date: DATE ERROR
New Start Date:

Workaround:
Use the Windows Administration console, Java console or command line to initiate the desired job.

ETA of Fix:
The formal resolution to this issue (Etrack 1395328) is included in the following patch release:
  • NetBackup 6.5 Release Update 4 (6.5.4)
This release is available at the Support web site at:
 http://www.symantec.com/business/support/downloads.jsp?pid=15143



Supplemental Materials

SourceETrack
Value1395328
DescriptionUsing bp interface on a IA64 11.23 client (also 11.31) produces a DATE ERROR when changing the date

Legacy ID



308809


Article URL http://www.symantec.com/docs/TECH63501


Terms of use for this information are found in Legal Notices