Incorrect function error occurs during a tape inventory if more than one type of tape drive is in an autoloader or library
| Article:TECH65487 | | | Created: 2008-01-24 | | | Updated: 2012-01-19 | | | Article URL http://www.symantec.com/docs/TECH65487 |
Problem
Incorrect function error occurs during a tape inventory if more than one type of tape drive is in an autoloader or library
Error
Incorrect function
Cause
For example, a library with LTO2 and LTO3 drives and tapes. Bar codes exist on the tape and bar code rules are enabled in Backup Exec.
Solution
Set the Barcode Rules to the rules of the barcode labels instead of using the prefix/suffix. Barcodes used are 0002xx for LTO2 tapes and 0003xx for LTO3 tapes.
|
|
Related Articles
Legacy ID
315349
Article URL http://www.symantec.com/docs/TECH65487
Terms of use for this information are found in Legal Notices









Thank you.