Serial Split brain error (V-5-1-10127) after adding a disk to an existing diskgroup
| Article:TECH69115 | | | Created: 2009-01-25 | | | Updated: 2010-01-05 | | | Article URL http://www.symantec.com/docs/TECH69115 |
Problem
Serial Split brain error (V-5-1-10127) after adding a disk to an existing diskgroup
Solution
If a disk is
removed from a diskgroup by mistake and when we try to add it back into the disk
group, we get an error about a split brain condition. This is because the disk
that was accidentally removed still has a ssbid in the private region. The
solution is to run the following command to override the ssbid and add the disk
back in to the diskgroup.
#
vxdg -g mydg -o overridessb adddisk mydg01=c5t0d0
|
|
Legacy ID
321594
Article URL http://www.symantec.com/docs/TECH69115
Terms of use for this information are found in Legal Notices









Thank you.