Hotfix for Symantec Enterprise Vault for File System Archiving 8.0 Service Pack 2 (SP2), Build 1693, While recalling files in bulk numbers from a pass-through enabled volume, the following error may occur on the File Server: 'The server was unable to allocate from the system nonpaged pool because the pool was empty'.

Article:TECH71897  |  Created: 2009-01-26  |  Updated: 2009-01-19  |  Article URL http://www.symantec.com/docs/TECH71897
Article Type
Technical Solution


Environment

Problem



Hotfix for Symantec Enterprise Vault for File System Archiving 8.0 Service Pack 2 (SP2), Build 1693, While recalling files in bulk numbers from a pass-through enabled volume, the following error may occur on the File Server: 'The server was unable to allocate from the system nonpaged pool because the pool was empty'.

Error



The server was unable to allocate from the system nonpaged pool because the pool was empty.

Solution



To which versions of Symantec Enterprise Vault (tm) can this hotfix be applied?
This hotfix can only be applied to the following versions of Enterprise Vault for:
Enterprise Vault 8.0 SP2


What issue does this hotfix resolve?
Recalling files in bulk numbers from a pass-through enabled volume, the following error may occur on the File Server: 'The server was unable to allocate from the system nonpaged pool because the pool was empty'.


Which files does this hotfix replace?
EvPlaceholderService.exe     8.0.2.1697
evmf.sys                                 8.0.2.1697


How to install this hotfix:
The following steps are to be performed on the File Server:

1. Stop Enterprise Vault File Placeholder Service.

2. Go to the command prompt and run the following command:

fltmc unload evfilter

3. Take a backup of the following files:

EvPlaceholderService.exe
Evmf.sys

4. Copy the following file provided in download to the Enterprise Vault installation folder:  

EvPlaceholderService.exe

5. Copy the evmf.sys file provided in the download from the appropriate folder x86 or x64 depending on the environment to the following location:

C:\Windows\system32\drivers

6. Go to the command prompt and run the following command:

fltmc load evfilter

7. Restart the Enterprise Vault File Placeholder Service.


How to uninstall this hotfix:

The following steps are to be performed on the File Server:

1. Stop Enterprise Vault File Placeholder Service.

2. Go to the command prompt and run the following command:

fltmc unload evfilter

3. Copy the following file from the backup location to the Enterprise Vault installation folder:  

EvPlaceholderService.exe

5. Copy the evmf.sys file from the backup location to the following location:

C:\Windows\system32\drivers

6. Go to the command prompt and run the following command:

fltmc load evfilter

7. Restart the Enterprise Vault File Placeholder Service.


Note: This issue has been addressed in the following release:

Enterprise Vault 8.0 SP3
 http://entsupport.symantec.com/docs/327168

Attachments

HF_For_ET_1542866_327168.zip (248 kBytes)

Supplemental Materials

SourceETrack
Value1542866
DescriptionDocument used to track this issue.

Legacy ID



327168


Article URL http://www.symantec.com/docs/TECH71897