Video Screencast Help

Search

Search results

The sort data collector is dependent on the fact that swap is configured on our systems. "The system on which you install the data collector must meet the following minimum requirements: * 500 MB free RAM * 300 MB free swap space * 2 ...
Idea by Angelika@1A | 09 Apr 2014 | 0 comments
I was looking for documentation about veritas check point. how to administer it. this is version 5.1 At first, I look through the "Vxfs admin guide". it asked me to looked at the "Advance feature guide" When I do, the ...
Idea by IdaWong | 21 Mar 2014 | 1 comment
Would it be possible to add the ability for the SFCFSHA script to automatically unmount filesystems as needed during a rolling upgrade?  We have many clusters that need to have disks under Veritas control mounted at boot, and would like to be able to use ...
Idea by Logan Doux | 31 Oct 2013 | 4 comments
we use VVR for migration.  once of the things you would want to do after the migration would be to remove the VVR setups  and it can be done without any downtime.  however, i had to dig here and there. couldn't find any procedure in any ...
Idea by IdaWong | 21 Mar 2014 | 0 comments
vxvm will remove all dmp devices due to di_init() failed when running "vxdisk scandisks" or "vxdctl enable" , and that result in all volume failed. vxvm should check all dmp devices whether they belong to any volume before remove ...
Idea by zhangjiahuan | 22 Oct 2013 | 1 comment
Please see https://www-secure.symantec.com/connect/blogs/cannot-remove-disabled-paths-while-path-part-disk-which-has-been-imported for linux as well, if you force removed the paths with echo 1 > /sys/block/$disk/device/delete there would ...
Idea by IdaWong | 24 Jul 2013 | 1 comment
In case # 04360304 we had a problem with DHC and DHC MAPS which not could be solved and there is no workaround.   We would like to be able to administer /switch off DHC/DHC MAP   Add to Add to /etc/opt/VRTSsfmh/xprtld.conf: ...
Idea by matloo | 20 Aug 2013 | 1 comment
Would like to have the ability to issue a "notification blackout" for Oracle's OEM product, prior to database resources going down.  The use of a "pre-offline type trigger" would be very beneficial, as this is needed per DB ...
Idea by jschmidt@federa... | 22 May 2013 | 0 comments
We need A Symantec support exception to obtain Symantec support for configurations with VxVM and Sun's Traffic Manager (MPxIO). Our intention is to substitute 2  Hitachi HDS USP ST9900V oem SUN with 2 new IBM DS8000 and/or IBM XIV storage. The ...
Idea by Carlos Ferruz | 18 Jul 2013 | 1 comment
In order to help the customers to identify the files involved in metadata corruption, the directory entries in a directory block should be printed before they are removed by fsck. For example, in pass 2, before removing a directory entry, please ...
Idea by Andrew_Law | 14 Jan 2013 | 2 comments