Clearwell Enterprise Vault Journal Collection Tasks hang at "Waiting for content retriever threads to exit..."

Article:TECH200072  |  Created: 2012-11-25  |  Updated: 2014-08-19  |  Article URL http://www.symantec.com/docs/TECH200072
Article Type
Technical Solution



Issue



Either when attempting to stop an Enterprise Vault (EV) Journal collection the task remains in 'Stopping' status or the Collection appears hung.  Inspection of the Job Status log repeats the line "Waiting for content retriever threads to exit..." 
  


Error



"Waiting for content retriever threads to exit..." 
 


Cause



No checking mechanism was in place to 'clean up' idle threads.

 


Solution



Resolved in version 7.1.2 FIX2

Symantec Corporation has acknowledged that the above-mentioned issue is present in the current version(s) of the product(s) mentioned at the end of this article. Symantec Corporation is committed to product quality and satisfied customers.

Symantec Corporation currently plans to address this issue by way of a patch or hotfix to the current version of the software. Please be sure to refer back to this document periodically as any changes to the status of the issue will be reflected here. A link to the patch or hotfix download will be added to this document when it becomes available. Please note that Symantec Corporation reserves the right to remove any fix from the targeted release if it does not pass quality assurance tests.  Symantec’s plans are subject to change and any action taken by you based on the above information or your reliance upon the above information is made at your own risk.

 

WORKAROUND:

1.  Stop, then start the collection task for hung collections.
2.  Restart Clearwell services for collections stuck in 'Stopping' mode.

 



Supplemental Materials

SourceJIRA
ValueESA-27836
Description

Perf: Problems stopping a large EV Collection task.



Article URL http://www.symantec.com/docs/TECH200072


Terms of use for this information are found in Legal Notices